Open Access
3 October 2013 Mesoscopic fluorescence molecular tomography of reporter genes in bioprinted thick tissue
Mehmet S. Ozturk, Vivian K. Lee, Lingling Zhao, Guohoa Dai, Xavier Intes
Author Affiliations +
Funded by: American Heart Association Scientist Development, National Institutes of Health, National Science Foundation (NSF), NSF CAREER AWARD
Abstract
Three-dimensional imaging of thick tissue constructs is one of the main challenges in the field of tissue engineering and regenerative medicine. Optical methods are the most promising as they offer noninvasive, fast, and inexpensive solutions. Herein, we report the use of mesoscopic fluorescence molecular tomography (MFMT) to image function and structure of thick bioprinted tissue hosted in a 3-mm-thick bioreactor. Collagen-based tissue assembled in this study contains two vascular channels formed by green fluorescent protein- and mCherry-expressing cells. Transfected live cell imaging enables us to image function, whereas Flash Red fluorescent bead perfusion into the vascular channel allows us to image structure. The MFMT optical reconstructions are benchmarked with classical microscopy techniques. MFMT and wide-field fluorescence microscopy data match within 92% in area and 84% in location, validating the accuracy of MFMT reconstructions. Our results demonstrate that MFMT is a well-suited imaging modality for fast, longitudinal, functional imaging of thick, and turbid tissue engineering constructs.

Tissue engineering is a promising technology that aims at replacing damaged tissues or organs for functional restoration.1 Three-dimensional (3-D) bioprinting technology is capable of manufacturing thick tissues as well as printing vasculatures.2 The resulting tissues are, however, thick (3mm), turbid, and hosted inside sealed bioreactors. Hence, it is difficult to employ traditional microscopic imaging methods to assess structure and function of the whole sample.

Optical imaging techniques, such as multiphoton or confocal microscopy, have been used in 3-D imaging of engineered tissues. Although they offer high resolution and great sensitivity, they are restricted in their penetration depth and field of view.3 For deeper imaging, optical coherence tomography (OCT) is the main optical imaging modality due to its high resolution (1 to 15 μm) in scattering tissue at depth up to 2mm.4 OCT is inherently a structural imaging method but also extracts functional information by elucidating structural changes.5,6 However, even though special markers have been devised,710 OCT is still limited in imaging molecular probes with high sensitivity. Especially, OCT is not sensitive to fluorescence signal, extensively employed in tissue engineering.

To probe a turbid sample beyond the microscopic penetration depth, a novel method was proposed,9 laminar optical tomography,10 or mesoscopic fluorescence molecular tomography (MFMT), also sometimes referred to as FLOT (Ref. 11) or MEFT.12 MFMT is able to image a few millimeters (3 to 5 mm) thick tissues with a relatively high resolution (100 to 200 μm).2 MFMT is well suited for in-vitro tomographic imaging,2 as well as for ex vivo12 and clinical imaging scenarios.13 Furthermore, it can be fused with other traditional optical imaging modalities such as OCT.11 One key advantage of MFMT is its ability to image a variety of fluorescent probes.

In this study, we have combined 3-D bioprinting and MFMT imaging modality. MFMT successfully retrieved the 3-D biodistribution of the live cells, expressing reporter genes, and a perfused vascular channel. MFMT was applied through a 3-mm-thick sealed chamber. This is a key step toward establishing MFMT as a useful imaging tool for tissue engineering applications.

MFMT imaging system is based on raster scanning a focused laser beam over the sample, Fig. 1(b). The fluorescence light is then detected at seven radial positions (di) away from the illumination spot in an epiconfiguration (d1=800μm, d7=3900μm).

Fig. 1

(a) Three-dimensional (3-D) bioprinting steps are depicted. Lower (purple) channel is mCherry. Upper (Green) is green fluorescent protein (GFP) channel. Lower (Red) in final step represents far-red fluorescent beads for perfusion. (b) Excitation signal (solid yellow) raster scanned over the sealed chamber. Emission signal (solid red) descanned and imaged on to detectors after filtering excitation signal.

JBO_18_10_100501_f001.png

The optical setup is similar to the one in Zhao et al.2 We have replaced the lenses with antireflective-coated achromatic ones and added one spectral channel. We have used emission filters (XB97/560BP10, Omega Optics; FF01-650/60-25, and FF01-700/13-25, Semrock) for corresponding Diode Laser source of 488, 589, and 658 nm, respectively. The focused beam impinges 17 mW on a circular area of 375 μm diameter on the chamber.

Emission signal and a matching background signal were acquired during raster scanning of the flow chamber over 3×7mm2 area, xy. The dwelling time at each collected source point was 8.3μs. The 3×7mm2 area imaged in this work lead to 80×200 source positions (Δx=37μm; Δy=35μm) and a total acquisition time of 132.8ms/frame (16,000 source position; corresponds to 7.5fps frame rate). Data acquisition was averaged over 1 min (450frames) to obtain fluorescent data with good signal-to-noise ratio. The averaged background signal was subtracted from averaged emission signal to minimize the autofluorescence and the bleed-through effect a posteriori. Reconstructions were performed using 14,400 laser beam positions, as artifacts originated from the software were observed on the border of the imaging area. Overall, the 14,400 source positions and data gathered from seven detectors for each laser beam position led to a total of 100,800 spatial data points. We used a CPU-based Monte Carlo photon propagation model to compute the Jacobian matrix. The forward simulations were carried with 105  photons and 0.2×0.2×0.2mm3 voxels. The optical properties, used to compute the Jacobian, were set at μs=5mm1, μa=0.002mm1, and g=0.9. These values were selected based on previous studies2 and reported values for collagen in the literature. Note that the optical properties were similar for all wavelengths investigated herein.

Human umbilical vein endothelial cells (HUVEC) were labeled with three different colors: GFP (λex/λem=488/507nm), mCherry (λex/λem=587/610nm), and far-red (λex/λem=650/670nm). Reporter genes were used for GFP and mCherry labeling (lentiviral transfection). For far-red, HUVECs were labeled with 5 μM far-red cell tracker [DiIC18(5)-DS, Invitrogen, Grand Island, New York]. The labeled cells were cultured at 37°C in 5% CO2 in endothelial cell growth medium-2 (Lonza, Allendale, New Jersey).

To validate the MFMT capability on reconstructing complex structures, “R,” “P,” “I,” 2-D letters were printed on collagen matrix (type I, 3.0mg/mL, BD Bioscience, San Jose, California) [Fig. 2(a)]. Far-red, GFP, and mCherry-labeled HUVECs were used to print ‘R’, ‘P’, and ‘I,’ respectively.

Fig. 2

(a) Fluorescent wide field microscopy (FWFM) image of R, P, I letters is expressing, Far-red cell tracker, GFP and mCherry, respectively. 3-D reconstruction is shown from top (b), from perspective (c) and side view image (d) shows the letters printed on the top of the collagen block sample (thin sample). Results show the accuracy of MFMT reconstruction as it is benchmarked against FWFM. Scale bar, 1 mm.

JBO_18_10_100501_f002.png

Through a layer-by-layer approach, two vascular channels were constructed inside of a 3-mm-thick sealed chamber (Fig. 1).1,2 GFP- and mCherry-expressing cells were seeded on the inner surface of top and bottom channels, respectively.

The distance between orthogonally located channels was varied (100 and 1300 μm) to test the imaging capability in different configurations. To visualize the channel structure, Flash Red beads (Bangs Laboratory Inc.) were perfused into the lower channel (mCherry cells seeded) at 0.1mL/min flow rate.

We benchmarked the 3-D reconstructions (RECONS) against two classical microscopic modalities (via maximum intensity projection): phase contrast microscopy (PCM) and fluorescent wide field microscopy (FWFM) (Eclipse Ti, Nikon). Accuracy of the reconstruction was quantified by segmentation of FWFM, PCM, and reconstruction images by an ImageJ plug-in (mixture modeling). Two metrics for objective image analysis were derived: area of segmented image (mm2) and agreement factor (AF). First, areas (AFWFM,APCM,ARECONS) and area ratios (ARECONS/AFWFM and ARECONS/APCM) were calculated. Then, overlap ratio was estimated: (ARECONSAFWFM)/ARECONS and (ARECONSAPCM)/ARECONS. Both area ratio and overlap ratio were lumped together in the AF: AF=2(|1Area ratio|+|1Overlap ratio|). If both the areas and locations, between modalities matched, AF=1.

MFMT successfully reconstructed the printed patterns regardless of the spectral range (green, red, and far-red) and labeling methods (cell tracker and reporter genes) [Fig. 2(a)]. The MFMT reconstruction results [Figs. 2(b)2(d)] matched the wide field images, demonstrating the ability of MFMT to recover the shape of the letters with accuracy. Area values for FWFM, PCM, and MFMT reconstruction are: 6.3, 6.86, 4.6mm2 for ‘R’; 5.44, 5.97, 4.33mm2 for ‘P’; 1.63, 2.78, 1.98mm2 for ‘I’. AF values of ‘R’, ‘P’, ‘I’ are 1.33, 1.31, and 1.25.

Two-channel collagen structures formed with varying channel-to-channel distance were constructed: orthogonal channels were printed closely (100μm), and far apart (1.3mm). In PCM imaging, the channels exhibited elliptic cross-sections estimated to be around 0.7 to 1.3 mm in width and 0.4 to 0.8 mm in height. Reconstruction for both cases and benchmarking against PCM and FWFM images are depicted in Figs. 3 and 4. The populations of GFP and mCherry cells were distinguished accurately in both cases. Channels were estimated to be 0.8 to 1 mm in width and 0.6 to 0.8 mm in height for GFP and mCherry, respectively (Fig. 3). Far apart channels had a width of 1.55 mm and 1.1 mm for GFP and mCherry, respectively, and a height of 0.5mm for both (Fig. 4). Overall, these dimensions were consistent with the values estimated by PCM. However, changes in temperature or inner-channel pressure caused slight expansion at channel edges, so this expansion also appeared in the MFMT reconstruction edges. Area values for FWFM, PCM, and reconstruction are: 3.93, 3.31, and 4.09mm2 for GFP; 6.13, 7.43, and 5.75mm2 for mCherry. AF values for FWFM and PCM are: 1.21, 1.49 for GFP and 1.16, 1.29 for mCherry. FWFM images are in better agreement with reconstruction values. This is an expected outcome as both FWFM and reconstruction are sensitive to the same contrast function.

Fig. 3

Phase contrast microscopy (PCM) (a) and FWFM image (GFP is green, mCherry is red) (b). Maximum intensity projections of MFMT reconstructions were merged (c). 3-D perspective image (d), top view (e) and side view (f) images, obtained from MFMT, show the position of vascular channels. GFP and mCherry channels are printed adjacent in 0.5 mm and 1 mm in depth, respectively. Scale bar, 1 mm.

JBO_18_10_100501_f003.png

Fig. 4

PCM (a) and FWFM image (GFP is green, mCherry is blue) (b). Maximum intensity projections of actual images were merged (c). 3-D perspective image (far-red is red) (d), bottom view and front view (f) images show the position of vascular channels. GFP and mCherry channels were printed in 0.5 and 2 mm, respectively. Black square in (b) is a FWFM defect that occurred while acquiring the data. PCM image provides us the location for GFP-expressing cells in that same location. Scale bar, 1 mm.

JBO_18_10_100501_f004.png

Additionally, Flash Red fluorescent beads perfusion through lower channel (mCherry) was reconstructed in 3-D (Fig. 4). The reconstructed beads flow was colocalized with lower channel reconstruction [Figs. 4(d)4(f)]. mCherry and beads flow reconstruction showed a slight discrepancy in the overall size. This may be due to the beads’ accumulation on the centerline of the channel during gentle beads perfusion (0.1mL/min). The problem can be addressed by applying a higher flow rate or using larger beads. A slight overlap was observed where two channels are adjacent (100μm) (Fig. 3), and this is attributed to voxel size of 200 μm. With higher computational cost, the voxel size can be decreased to increase the image space resolution and, hence, separate channels more accurately. We also note that the optical properties were kept constant for all reconstructions. Hence, a slight mismatch between true and simulated optical properties over the spectral range of the system was induced. The impact of optical property mismatch between the light propagation model and the sample has been studied for diffuse optical tomography (Ref. 14) and we are currently investigating the effect of this mismatch on MFMT performance. We expect it to be the main source of mismatch between microscopy and MFMT reconstructions observed in this study.

In this study, we have demonstrated 3-D fluorescence reconstruction of live, reporter gene expressing cells, and perfusion through vascular channels in 3-mm engineered tissue constructs within a (this can be also performed via Doppler OCT) bioreactor. The whole imaging, data acquisition and reconstruction, was completed in less than 5 min for each fluorophore.

Our results, as well as the previous studies,2 show the potential of MFMT as a powerful tool for tissue engineering applications. We believe that MFMT will have an important role to localize and monitor live fluorescent cells in thick tissue. This is a cost- and time-effective technique to evaluate the dynamic progression and functional status of engineered tissues prior to host implantation. In future studies, we plan to employ this technique to assess the maturation process of printed vasculature as well as in-vivo imaging.

Acknowledgments

This work was partly funded by the American Heart Association Scientist Development Grant SDG12050083, National Institutes of Health grant R21 HL102773 and NSF CAREER AWARD CBET- 1149407, NSF CBET-1263455.

References

1. 

W. Leeet al., “On-demand three-dimensional freeform fabrication of multi-layered hydrogel scaffold with fluidic channels,” Biotechnol. Bioeng., 105 (6), 1178 –1186 (2010). http://dx.doi.org/10.1002/bit.22613 BIBIAU 0006-3592 Google Scholar

2. 

L. Zhaoet al., “The integration of 3-D cell printing and mesoscopic fluorescence molecular tomography of vascular constructs within thick hydrogel scaffolds,” Biomaterials, 33 (21), 5325 –5332 (2012). http://dx.doi.org/10.1016/j.biomaterials.2012.04.004 BIMADU 0142-9612 Google Scholar

3. 

E. HooverJ. Squier, “Advances in multiphoton microscopy technology,” Nat. Photonics, 7 (2), 93 –101 (2013). http://dx.doi.org/10.1038/nphoton.2012.361 NPAHBY 1749-4885 Google Scholar

4. 

J. G. Fujimoto, Optical Coherence Tomography, Technology and Applications, 1 Springer, New York (2011). Google Scholar

5. 

W. Tanet al., “Structural and functional optical imaging of three-dimensional engineered tissue development,” Tissue Eng., 10 (11–12), 1747 –1756 (2004). http://dx.doi.org/10.1089/ten.2004.10.1747 1937-3341 Google Scholar

6. 

R. Leitgebet al., “Real-time measurement of in vitro flow by Fourier-domain color Doppler optical coherence tomography,” Opt. Lett., 29 (2), 171 –173 (2004). http://dx.doi.org/10.1364/OL.29.000171 OPLEDP 0146-9592 Google Scholar

7. 

A. L. OldenburgJ. R. GuntherS. A. Boppart, “Imaging magnetically labeled cells with magnetomotive optical coherence tomography,” Opt. Lett., 30 (7), 747 –749 (2005). http://dx.doi.org/10.1364/OL.30.000747 OPLEDP 0146-9592 Google Scholar

8. 

K. D. Raoet al., “Molecular contrast in optical coherence tomography by use of a pump-probe technique,” Opt. Lett., 28 (5), 340 –342 (2003). http://dx.doi.org/10.1364/OL.28.000340 OPLEDP 0146-9592 Google Scholar

9. 

A. DunnD. Boas, “Transport-based image reconstruction in turbid media with small source-detector separations,” Opt. Lett., 25 (24), 1777 –1779 (2000). http://dx.doi.org/10.1364/OL.25.001777 OPLEDP 0146-9592 Google Scholar

10. 

E. M. C. Hillmanet al., “Laminar optical tomography: demonstration of millimeter-scale depth-resolved imaging in turbid media,” Opt. Lett., 29 (14), 1650 –1652 (2004). http://dx.doi.org/10.1364/OL.29.001650 OPLEDP 0146-9592 Google Scholar

11. 

S. Yuanet al., “Three-dimensional coregistered optical coherence tomography and line-scanning fluorescence laminar optical tomography,” Opt. Lett., 34 (11), 1615 –1617 (2009). http://dx.doi.org/10.1364/OL.34.001615 OPLEDP 0146-9592 Google Scholar

12. 

S. BjörnV. NtziachristosR. Schulz, “Mesoscopic epifluorescence tomography: reconstruction of superficial and deep fluorescence in highly-scattering media,” Opt. Express, 18 (8), 8422 –8429 (2010). http://dx.doi.org/10.1364/OE.18.008422 OPEXFF 1094-4087 Google Scholar

13. 

T. J. Muldoonet al., “Analysis of skin lesions using laminar optical tomography,” Biomed. Opt. Express, 3 (7), 1701 –1712 (2012). http://dx.doi.org/10.1364/BOE.3.001701 BOEICL 2156-7085 Google Scholar

14. 

X. ChengD. Boas, “Systematic diffuse optical image errors resulting from uncertainty in the background optical properties,” Opt. Express, 4 (8), 299 –307 (1999). http://dx.doi.org/10.1364/OE.4.000299 OPEXFF 1094-4087 Google Scholar
© 2013 Society of Photo-Optical Instrumentation Engineers (SPIE) 0091-3286/2013/$25.00 © 2013 SPIE
Mehmet S. Ozturk, Vivian K. Lee, Lingling Zhao, Guohoa Dai, and Xavier Intes "Mesoscopic fluorescence molecular tomography of reporter genes in bioprinted thick tissue," Journal of Biomedical Optics 18(10), 100501 (3 October 2013). https://doi.org/10.1117/1.JBO.18.10.100501
Published: 3 October 2013
Lens.org Logo
CITATIONS
Cited by 55 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Tissues

Green fluorescent protein

Luminescence

Tomography

Microscopy

Fluorescence tomography

Tissue engineering

Back to Top