1.IntroductionSpinal cord injury (SCI) is a severe medical condition resulting in motor and sensory deficits, with dramatic functional and socioeconomic impacts.1 The pathophysiology of SCI includes axonal severing and loss of neuronal fibers, with failure to sustain a regenerative response that can reconnect long descending motor tracts and ascending sensory fibers. Multiple long-term factors contribute to regeneration failure. After injury, the axons originating in descending cortical and subcortical tracts exhibit dieback over one or more segments, but do not degenerate to the cell body. Additionally, glial scar formation results in a chemical and physical barrier to reconnection of descending motor axons below the lesion.2–4 We have recently demonstrated the capacity of poly(lactide-co-glycolide) (PLG) bridges implanted into a C5 cervical hemisection injury to promote regeneration of the descending corticospinal tract (CST). In that study, CST fibers expressing a green fluorescent protein (GFP) reporter exhibited growth through the bridge and into the distal spinal cord,5 supporting implantation of PLG bridges as a substrate for axonal regeneration.6 Implantation of this type of scaffolding biomaterial is applicable to SCI models, in which a surgical incision has been made to remove a segment or more of spinal cord, and potentially to traumatic clinical injuries, in which there has been penetration of the gray and white matter of the spinal cord. Current clinical applications of PLG include advanced drug delivery systems, dental sciences, and biodegradable bone grafts.7 Evaluation of axonal damage, myelination, and axonal regeneration is critical to investigate regeneration dynamics after SCI or in other implantation paradigms. Accordingly, we sought to develop a tool to identify neuronal fiber growth in a mouse model of SCI, using confocal and two-photon imaging on live animals. This imaging approach demonstrates proof of concept for in vivo imaging within the spinal cord lesion and regenerative fibers with the potential to evaluate remyelination on in situ spinal cord section. In vivo imaging studies of axon trajectories and neuronal fibers after SCI enable unambiguous identification of spared, injured, and regenerating neuronal fibers, providing a strong stage to assess therapies aimed at spurring neuronal fiber growth.8 We used Thy1-enhanced green fluorescent protein (eGFP) mice, which have previously been employed in other neurobiological studies and are commercially available.9,10 These mice express eGFP in neuronal areas, including the spinal cord, enabling visualization of axons of multiple origins. We used a modified upright two-photon microscope equipped for live animal imaging, capable of visualizing fluorescent emission originating from eGFP. We used the same microscope to visualize third-harmonic emission signals arising from myelin on spinal cord sections.11,12 Myelin is a compact fatty structure that wraps axons to enhance the speed of signal transmission.13 Myelin can be detected via third-harmonic emission signals in the intact spinal cord; in contrast, myelin identifying dyes can only be applied in fixed tissue sections and disrupt its lipid structure.12 We visualized fluorescence inside the intact spinal cord rostral and caudal to the lesion site, as well as that inside the PLG bridge arising from regrown neuronal fibers. We then sectioned the spinal cord and visualized the eGFP fluorescence signal through the PLG bridge, and we evaluated the third-harmonic signal to investigate possible fibers remyelination. Third-harmonic generation (THG) is a suitable method to detect myelin inside the central nervous system (CNS).12,14 THG can be detected from myelin in a label-free imaging modality that provides micrometer resolution imaging of myelin in the mouse spinal cord.14,12 Using this method, we tried to assess axonal myelination adjacent to and inside the PLG bridge. We were able to visualize third-harmonic signal rostral to the bridge entrance, but not inside the bridge. However, our qualitative results show it is possible using reporter mice to visualize a time-lapse regrowth of spinal cord fibers through a PLG bridge. 2.Methods2.1.Poly(Lactide-Co-glycolide) BridgeSynthetic PLG bridges were fabricated by adapting a previously established gas foaming/particulate leaching procedure to include caramelized sucrose fibers as a channel template.6,15,16 The final bridge dimensions were 1.25 mm in height, 1.15 mm in length (R-C), and 0.75 mm in width (M-L) [Fig. 2(a)]. The channels were characterized and bridge diameters measured (n=6) using light microscopy images (Leica Microsystems, Wetzlar, Germany) and ImageJ software. The cross-sectional area occupied by the channels and the porosities of these bridges were calculated using equations established previously.17 Bridges were imaged using the field emission scanning electron microscopy (Zeiss Leo Gemini 1525, Jena, Germany) at 10 kV after coating with osmium tetra oxide. 2.2.Spinal Cord Injury and AnimalsAll animal housing conditions, surgical procedures, and postoperative care were conducted according to IACUC guidelines at the University of California, Irvine. Female mice were anesthetized using isoflurane (2%). Mice received a C5 laminectomy, followed by a left-sided lateral hemisection and removal of a unilateral 1- to 1.1-mm segment of the spinal cord to enable bridge implantation into the resulting gap [Fig. 2(c)]. In some instances, the gap was too wide in the medial-lateral direction, and two bridges were placed into the gap side-by-side to prevent shifting of the implanted bridge and ensure stable apposition with the rostral and caudal spinal cord over time. A length standard was used to create the hemisection gap, to ensure that the length of the bridge would be greater than the length of the hemisection and ensure good apposition of the multichannel bridge to the spared rostral and caudal spinal cord. PLG multichannel bridges were implanted into the gap immediately after SCI in Thy1-eGFP (JAX 007788; N=3). We repeated the experiment on three different animals, with the best case represented in the figures except for Fig. 3(d) where we show the variability of neuronal regrowth in the other two animals we tested. The laminectomy site was covered with gel foam to prevent the formation of muscle adhesions. Muscle was sutured over the laminectomized region with 5-0 chromic gut, and skin was closed with wound clips. Animals were maintained under bladder care for 8 weeks according to IACUC approved protocols. Postoperative care also included administration of Baytril (enrofloxacin 2.5 mg/kg, once a day for 2 weeks), buprenorphine (0.1 mg/kg twice a day for 3 days), and lactated ringers solution (5 mL/100 g, once a day for 5 days). Mice were euthanized 12 weeks postlesion/bridge implantation; mice were anesthetized with sodium pentobarbital (100 mg/kg, i.p.) and transcardially perfused with 30 ml phosphate-buffered saline (PBS). Spinal cords were dissected based on vertebral level and the C2-T1 region collected for sectioning followed by THG imaging and histology. 2.3.Microscopy and Live ImagingLive imaging was performed at day 0, immediately before SCI and bridge implantation to establish a baseline, and 8 weeks post-SCI and PLG bridge implantation. Animals were anesthetized using isoflurane (2%) and kept on a warming pad to maintain temperature at 37°C for all procedures; live imaging was completed within a 1-h time limit after the animals were anesthetized [Fig. 2(b)]. During imaging, the vertebral column was stabilized by clamping forceps placed on the C4 and C6 vertebrae and attached to a fixation apparatus to prevent movement of the cord. Images were acquired using an commercial upright microscope (Olympus BX module, Center Valley, Pennsylvania) coupled to a tunable femtosecond pulsed Ti:sapphire laser (Mai Tai HP with pulse-width compensator unit DeepSee, Spectra Physics, Santa Clara, California) working at 80 MHz. The setup was equipped with two digital photon counting PMTs (H7422P, Hammatsu, Japan) in the reflective path and a wide area PMT (R7600P-300, Hamamatsu, Japan) in the transmission path of excitation. A photon time tagging unit capable of lifetime imaging (FLIM-Box, ISS, Urbana-Champaign, Illinois) was used to collect the signals from the PMTs, enabling simultaneous detection and imaging. The imaging and data analysis were performed using the lab-made software (SimFCS, LFD). The third-harmonic images were imaged at 1038 nm (THG at ∼346 nm) and collected with a narrow bandpass filter combination of glass filters (BG39 and UG11, Edmund Optics, Barrington, New Jersey) centered at 360±25 nm. The single-photon confocal imaging was done using microscope’s internal 473-nm diode laser. Images were collected by raster scanning at fixed pixel dwell time of 20 μs/pixel and image size of 256×256. The scanning was controlled by SimFCS for THG and Olympus Fluoview for confocal imaging. A schematic representation of the microscope and data collection is shown in Fig. 1. Fig. 1Download2.4.Third-Harmonic Generation ImagingSpinal cords were obtained from the same animals used for live imaging 12 weeks post-SCI and bridge implantation. The cords were cryosectioned horizontally at 160 μm and sections evaluated for THG imaging. We perfused the animals using cold PBS and we carefully removed the cord segment C2-T1. Cord were immediately frozen using Histobath (Thermo Shandon). Cords were sectioned using cryostat (Thermo Scientific). For sectioning, spinal cords were carefully aligned to show linear apposition between the spinal parenchyma and bridge and reveal the bridge channels through which axonal regeneration occurs.5 We imaged the regions across the bridge 500-μm rostral and caudal, respectively. A large area detector for deep tissue imaging termed as the DIVER18 was employed for enhanced transmitted THG collection. We used 1038 nm as excitation and we collected the signal using a bandpass filter at 320 nm. This module has automated filter wheel switching between conventional fluorescence emission spectral bands and narrower THG bands. THG is a nonlinear optical phenomenon that is produced by sufficiently high energy/photon density obtained through tightly focused light of ultrafast pulses of short duration of hundred femtoseconds. Nonlinear microscopy always found its home in neuronal imaging because of the inherent challenge in imaging deep through a scattering brain tissue.19 Nonlinear fluorescence excitation methods, such as two-photon fluorescence,20 three-photon fluorescence,21 four-photon fluorescence,22,23 have been reported in multiphoton imaging. Similarly, nonlinear scattering phenomena, such as second-harmonic generation or THG, are used in the same imaging modality. Fluorescence is bound by the absorption cross section (two photons) for the fluorophores (eGFP) and their values can be found in the literature.24–26 In contrast to absorption, THG imaging is a coherent process produced by the broken axial focal symmetry because of nonlinear susceptibility changes in the focal plane. The localized THG signal provides high axial resolution and excellent contrast of changes in refractive index. Briefly, refreshing the third-order nonlinear processes, the induced polarization from the third-order susceptibility [χ(3)] is P3i=ε0∑xyzχ(3)iEw, where E is the incident electric field of frequency (w) and X(3) is a fourth-rank tensor that multiplies E(x), E(y), E(z), the electric field in three axes. It can be proven that the essential phase-matching condition for THG is refractive indices relation: n(w)−n(3w)=0, which restricts the THG only special cases where the refractive index of fundamental (w) matches the refractive index of the THG (3w). We performed THG measuring on mice spinal cord slides as described in Sec. 2.2. 3.ResultsFor the live imaging of the cord, animals were maintained under anesthesia for the duration of the experiment and positioned under the microscope as shown [Fig. 2(b)]. An initial (0 day) live imaging session on the Thy1-eGFP animals was performed immediately prior to SCI and bridge implantation to establish the capacity to detect in vivo neuronal fibers. Using a 488-nm (blue) laser, we imaged the eGFP neuronal fibers through cord up to 140-μm deep inside the tissue [Fig. 2(d)]. We were able to observe very distinct neuronal fibers inside the cord, expressing eGFP. Fig. 2DownloadAfter the initial imaging session, we performed a C5 hemisection and bridge implantation as described in Sec. 2.2 [Figs. 2(a) and 2(c)]. For bridge implantation, the dimensions of the biomaterial bridge were adapted to the lesion size to ensure apposition within the lesion margins of the hemisection. A second live imaging session was performed 8 weeks post-SCI and bridge implantation, with anesthesia and acquisition time limited to 1 h for data collection. We used reflectance microscopy to detect the bridge and green fluorescence (eGFP) to image the neuronal fibers. We imaged rostral to and within the PLG bridge to establish feasibility to identify regrown fibers entering the bridge and traversing through it. Figure 3(a) shows a schematic representation of the bridge placed inside the spinal cord at C5 level. Numerous green fluorescent neuronal fibers were observed to accumulate in the rostral parenchyma [Fig. 3(b)], where they were positioned immediately adjacent to the entrance to the PLG bridge. Although few fibers were found to enter the bridge channels at this timepoint in the Thy1 model, we were able to observe some [Figs. 3(c) and 3(d)]. These fibers reached distances of up to ∼500 μm from the rostral side of the injury edge, progressing toward the caudal margin. Fig. 3DownloadFollowing the imaging session, animals were resutured and maintained for an additional 4 weeks. At 12 weeks post-SCI and bridge implantation, animals were euthanized as described in Sec. 2 to confirm the observation of regenerated fibers within the bridge in histological sections and to test THG imaging for the visualization of myelinated fibers within the bridge. C2-T1 spinal cord segments were cryosectioned horizontally at 160 μm to enable comparison of injured and uninjured spinal parenchyma, as well as regions rostral to, within, and caudal to the implanted bridge. Cryosections were mounted on glass slides as described in Sec. 2. PLG biomaterial bridges exhibit a degradation profile.16 Using these procedures, we were able to observe the degrading bridges inside the tissue at C5 level [Fig. 4(a)] and histologically verify the presence of regenerating neuronal fibers. We observed increased green fluorescence (eGFP) arising from the area proximal to the bridges in both rostral and caudal area [Figs. 4(a) and 4(b)]. We speculate the presence of high fluorescence at bridge boundaries is due to the regenerating neuronal fibers accumulating at the bridge entrance. In Fig. 4(a), the green fluorescence is evidently present across the whole injury, suggesting that many more neuronal fibers have crossed the bridge in the 4 weeks after the live imaging session. This timecourse is in agreement with our previous publications in which we observed the neuronal fibers starting to enter the bridge and crossing through it in 4 to 12 weeks postinjury.5 Fig. 4DownloadAdditionally, we tested the detection of THG signal within the bridge, as described in Sec. 2. THG has been demonstrated to be capable of imaging compact myelin in Schwann cells and in the CNS ex vivo.12,14 We tested this possibility by applying the same method to study the remyelination of the spinal cord after injury. Figure 5(a) illustrates detection of GFP+ axons in the rostral spinal parenchyma adjacent to the bridge using region reflectance microscopy. Figure 5(b) demonstrates successful detection of THG signal associated with these axons. However, while we were able to detect THG from neuronal fibers in the rostral parenchyma and fluorescent eGFP+ fibers throughout the bridge structure [Fig. 5(c)], we were unable to detect any THG signal within the bridge [Fig. 5(d)]. Taken together, these data suggest that the myelination is a process that does not directly follow the neuronal fibers regeneration and could occur at a later time. Fig. 5Download4.DiscussionEvaluation of axonal damage, myelination, and axonal regeneration is critical to investigate the dynamics of regeneration after SCI. In vivo studies of neuronal fibers after SCI would improve knowledge of regenerating fibers growing into and through a permissive environment, such as the PLG bridge. This approach is also important as a strategy for improving understanding of axonal regeneration and sprouting in the spared parenchyma of the spinal cord after injury. Visualizing the regrowth of the neuronal fibers would enable us to investigate the direction of regeneration and eventually investigate any physical barrier slowing the regeneration process. For many fiber tracts, reconstructing a circuit through regeneration or regenerative sprouting may be only the first step in establishing functional connectivity. In this regard, myelination of these new fibers will in many cases be a determining factor. Assessing the level of axonal myelination in vivo is a challenging task because the third-harmonic signal is easily absorbed from the tissues and along the microscope pathway, limiting the detection signal. However, it is possible to obtain myelination data from ex vivo fibers. Here, we demonstrate the feasibility of combining live imaging of neuronal regrowth at two separate time-points, before and after the PLG scaffold implantation, with ex vivo determination of myelination status of these fibers. Myelination in the spinal cord after PLG bridges implant has been demonstrated previously to be very low.27 When PLG bridges were implanted without trophic factors or sonic hedgehog only 18% of fibers exhibited colabeling for neurofilament and myelin basic protein 8 weeks postimplant. Although we were unable to detect any signal arising from THG in the PLG bridge area, we cannot exclude that the absence of myelination is due to the properties of the bridge. For example, the signal arising from the myelin could be quenched given the low proportion of myelinated fibers at this time point. Additionally, THG has only been used to visualize mature myelinated structures, in which compact myelin has formed;11,12 thus, it is also possible that we were unable to visualize THG signal due to the immature state of the myelin at this time point. Critically, three-photon imaging and THG microscopy have the potential to go deeper than two-photon imaging schemes, owing to greater penetration depth due to using a longer wavelength. Three-photon imaging and THG microscopy also render higher resolution images because of the spatial excitation photon density in a third-order nonlinear process. However, one main hurdle in increasing depth of imaging is the wavefront distortion suffered by the excitation beam through scattering in the layers of penetrated tissue thinning excitation photon density. This can be corrected by adaptive optics schemes28 and other photon density optimizing techniques to focus the light at one point using objective lens optimization.29 Future development of these systems will lead to an improvement into the live imaging of the spinal cord and to detect myelination in an in vivo setting. AcknowledgmentsFunding for this work was provided by the National Institutes of Health (NIH) 5R01EB005678-12 (L.D.S., A.J.A., and B.J.C.) and the Christopher and Dana Reeve Foundation (A.J.A.) and NIH P41-RR03155 (M.A.D.). ReferencesA. E. Chiodo et al.,
“Spinal cord injury medicine. 5. Long-term medical issues and health maintenance,”
Arch. Phys. Med. Rehabil., 88 S76
–S83
(2007). https://doi.org/10.1016/j.apmr.2006.12.015 APMHAI 0003-9993 Google Scholar
J. Silver and J. H. Miller,
“Regeneration beyond the glial scar,”
Nat. Rev. Neurosci., 5 146
–156
(2004). https://doi.org/10.1038/nrn1326 NRNAAN 1471-003X Google Scholar
J. L. Nielson, M. K. Strong and O. Steward,
“A reassessment of whether cortical motor neurons die following spinal cord injury,”
J. Comp. Neurol., 519 2852
–2869
(2011). https://doi.org/10.1002/cne.22661 JCNEAM 0021-9967 Google Scholar
P. Freund et al.,
“Degeneration of the injured cervical cord is associated with remote changes in corticospinal tract integrity and upper limb impairment,”
PLoS One, 7 e51729
(2012). https://doi.org/10.1371/journal.pone.0051729 POLNCL 1932-6203 Google Scholar
K. Pawar et al.,
“Biomaterial bridges enable regeneration and re-entry of corticospinal tract axons into the caudal spinal cord after SCI: association with recovery of forelimb function,”
Biomaterials, 65 1
–12
(2015). https://doi.org/10.1016/j.biomaterials.2015.05.032 BIMADU 0142-9612 Google Scholar
A. M. Thomas et al.,
“Channel density and porosity of degradable bridging scaffolds on axon growth after spinal injury,”
Biomaterials, 34 2213
–2220
(2013). https://doi.org/10.1016/j.biomaterials.2012.12.002 BIMADU 0142-9612 Google Scholar
A. Vats et al.,
“Scaffolds and biomaterials for tissue engineering: a review of clinical applications,”
Clin. Otolaryngol. Allied Sci., 28 165
–172
(2003). https://doi.org/10.1046/j.1365-2273.2003.00686.x Google Scholar
M. J. Farrar et al.,
“Chronic in vivo imaging in the mouse spinal cord using an implanted chamber,”
Nat. Methods, 9 297
–302
(2012). https://doi.org/10.1038/nmeth.1856 1548-7091 Google Scholar
G. Feng et al.,
“Imaging neuronal subsets in transgenic mice expressing multiple spectral variants of GFP,”
Neuron, 28 41
–51
(2000). https://doi.org/10.1016/S0896-6273(00)00084-2 NERNET 0896-6273 Google Scholar
C. Laperchia et al.,
“Two-photon microscopy imaging of thy1GFP-M transgenic mice: a novel animal model to investigate brain dendritic cell subsets in vivo,”
PLoS One, 8 e56144
(2013). https://doi.org/10.1371/journal.pone.0056144 POLNCL 1932-6203 Google Scholar
A. J. Schain, R. A. Hill and J. Grutzendler,
“Label-free in vivo imaging of myelinated axons in health and disease with spectral confocal reflectance microscopy,”
Nat. Med., 20 443
–449
(2014). https://doi.org/10.1038/nm.3495 1078-8956 Google Scholar
M. J. Farrar et al.,
“In vivo imaging of myelin in the vertebrate central nervous system using third harmonic generation microscopy,”
Biophys. J., 100 1362
–1371
(2011). https://doi.org/10.1016/j.bpj.2011.01.031 BIOJAU 0006-3495 Google Scholar
E. M. Gibson, A. C. Geraghty and M. Monje,
“Bad wrap: myelin and myelin plasticity in health and disease,”
Dev. Neurobiol., 78 123
–135
(2018). https://doi.org/10.1002/dneu.22541 Google Scholar
H. Lim et al.,
“Label-free imaging of Schwann cell myelination by third harmonic generation microscopy,”
Proc. Natl. Acad. Sci. U. S. A., 111 18025
–18030
(2014). https://doi.org/10.1073/pnas.1417820111 Google Scholar
H. M. Tuinstra et al.,
“Multifunctional, multichannel bridges that deliver neurotrophin encoding lentivirus for regeneration following spinal cord injury,”
Biomaterials, 33 1618
–1626
(2012). https://doi.org/10.1016/j.biomaterials.2011.11.002 BIMADU 0142-9612 Google Scholar
L. De Laporte et al.,
“Plasmid releasing multiple channel bridges for transgene expression after spinal cord injury,”
Mol. Ther., 17 318
–326
(2009). https://doi.org/10.1038/mt.2008.252 Google Scholar
M. J. Moore et al.,
“Multiple-channel scaffolds to promote spinal cord axon regeneration,”
Biomaterials, 27 419
–429
(2006). https://doi.org/10.1016/j.biomaterials.2005.07.045 BIMADU 0142-9612 Google Scholar
V. Crosignani, A. S. Dvornikov and E. Gratton,
“Enhancement of imaging depth in turbid media using a wide area detector,”
J. Biophotonics, 4 592
–599
(2011). https://doi.org/10.1002/jbio.201100001 Google Scholar
W. R. Zipfel, R. M. Williams and W. W. Webb,
“Nonlinear magic: multiphoton microscopy in the biosciences,”
Nat. Biotechnol., 21 1369
–1377
(2003). https://doi.org/10.1038/nbt899 NABIF9 1087-0156 Google Scholar
W. Denk, J. H. Strickler and W. W. Webb,
“Two-photon laser scanning fluorescence microscopy,”
Science, 248 73
–76
(1990). https://doi.org/10.1126/science.2321027 SCIEAS 0036-8075 Google Scholar
S. Maiti et al.,
“Measuring serotonin distribution in live cells with three-photon excitation,”
Science, 275 530
–532
(1997). https://doi.org/10.1126/science.275.5299.530 SCIEAS 0036-8075 Google Scholar
S. W. Chu et al.,
“Simultaneous four-photon luminescence, third-harmonic generation, and second-harmonic generation microscopy of GaN,”
Opt. Lett., 30 2463
–2465
(2005). https://doi.org/10.1364/OL.30.002463 OPLEDP 0146-9592 Google Scholar
F. E. Hernandez et al.,
“Three- and four-photon absorption of a multiphoton absorbing fluorescent probe,”
Appl. Opt., 43 5394
–5398
(2004). https://doi.org/10.1364/AO.43.005394 APOPAI 0003-6935 Google Scholar
M. A. Albota, C. Xu and W. W. Webb,
“Two-photon fluorescence excitation cross sections of biomolecular probes from 690 to 960 nm,”
Appl. Opt., 37 7352
–7356
(1998). https://doi.org/10.1364/AO.37.007352 APOPAI 0003-6935 Google Scholar
L. C. Cheng et al.,
“Measurements of multiphoton action cross sections for multiphoton microscopy,”
Biomed. Opt. Express, 5 3427
–3433
(2014). https://doi.org/10.1364/BOE.5.003427 BOEICL 2156-7085 Google Scholar
C. Xu et al.,
“Multiphoton fluorescence excitation: new spectral windows for biological nonlinear microscopy,”
Proc. Natl. Acad. Sci. U. S. A., 93 10763
–10768
(1996). https://doi.org/10.1073/pnas.93.20.10763 Google Scholar
A. M. Thomas et al.,
“Sonic hedgehog and neurotrophin-3 increase oligodendrocyte numbers and myelination after spinal cord injury,”
Integr. Biol., 6 694
–705
(2014). https://doi.org/10.1039/C4IB00009A 1757-9708 Google Scholar
G. Norris et al.,
“A promising new wavelength region for three-photon fluorescence microscopy of live cells,”
J. Microsc., 246 266
–273
(2012). https://doi.org/10.1111/j.1365-2818.2012.03610.x JMICAR 0022-2720 Google Scholar
D. Sinefeld et al.,
“Adaptive optics in multiphoton microscopy: comparison of two, three and four photon fluorescence,”
Opt. Express, 23 31472
–31483
(2015). https://doi.org/10.1364/OE.23.031472 OPEXFF 1094-4087 Google Scholar
|