1.IntroductionDigital holographic microscopy (DHM) is a label-free microscopy technique providing accurate and time-resolved quantitative phase information of transparent biological samples.1–3 In contrast to other label-free techniques such as bright field, Zernike phase contrast,4 and differential interference contrast (DIC) microscopy,5 DHM quantitatively recovers the optical path delay of the light passing through semi-transparent samples.6,7 This enables quantitative phase imaging (QPI) with up to a nanometer sensitivity and extended depth of field, employing a non-invasive, full-field, real-time capable, non-contact, and static (without mechanical parts) operational principle.8–11 In earlier studies, various biomedical applications of DHM3,12,13 were demonstrated; these include cancer research,14–16 in vitro cytotoxicity testing,17–19 cell manipulation monitoring,20 immune cell analysis,21–23 sperm cell assessment,24,25 detection of viral infections,26 diabetes screening,27 and SARS-Cov-2 detection and classification.28 Digital lensless holographic microscopy (DLHM) is a variant of DHM and offers a simple and compact microscopy scheme with high resolution and a wide field of view (FOV)29 by implementing a digital version of Gabor’s initial holography approach,30 in which a point source illuminates the sample in transmission and a digital sensor records the diffraction pattern.31 Then, the sample image is recovered by numerical propagation from the recording/hologram plane to the image plane.32 However, the initially proposed in-line holographic configuration causes an overlap between the numerically focused image and the unfocused diffraction pattern of the conjugate complex twin image. This overlap not only affects the quality of the final image by reducing the signal-to-noise ratio (SNR) but also prevents an accurate acquisition of QPI images.29 Various approaches have been developed to address the twin-image problem in DLHM.33–49 These approaches include phase-shifting techniques33,34 and multi-height phase-retrieval procedures,35,42–49 which require recording multiple holograms to eliminate the twin image contribution. However, these earlier reported methods are limited or not suitable for fast dynamic events due to the need for multiple hologram recordings. Alternatively, single-shot techniques, which allow for twin-image-free image reconstruction from a single hologram, have been devised.36–41 These methods typically rely on iterative phase-retrieval algorithms with object mask constraints36,37 or multi-wavelength illumination.38–41 Although effective in mitigating the twin image, iterative algorithms can be computationally intensive and prone to convergence issues.50 Other approaches involved deep learning, which showed promising results in rapidly removing the twin image for specific applications, although they required training the algorithm with a substantial amount of suitable ground-truth data.51–55 An alternative approach to overcoming the twin-image problem in DLHM involves adopting an off-axis DLHM configuration.56–59 The off-axis approach allows for image reconstruction from single captured holograms without twin image presence and without a requirement for recording multiple images, iterative algorithms, object constraints, multi-illumination sources, or machine learning. For example, Lu et al.56 utilized an off-axis DLHM setup using two pinholes to achieve an interferometric configuration. Serabyn et al.57 employed a pair of small gradient-index (GRIN) lenses for off-axis holographic recording. Rostykus and Moser58 proposed the use of a prism with a photopolymer layer to record two-volume hologram gratings, enabling the implementation of an off-axis lensless configuration. In addition, Ebrahimi et al.59 presented a common-path off-axis DLHM scheme that utilizes a Fresnel biprism to generate two spherical waves for off-axis holographic recordings. Here, we report on a common-path off-axis DLHM approach entitled LEnslesS spatially multiplexed interferometric microscopy (LESSMIM) to achieve both, single-shot QPI and twin-image elimination. LESSMIM is inspired by a previously reported DHM technique known as spatially multiplexed interferometric microscopy (SMIM),60–63 which extended a bright field microscope to a holographic one by introducing coherent illumination, leaving a clear region at the sample plane, and incorporating a diffraction grating. SMIM has been applied for super-resolution imaging,64,65 noise-reduced QPI,61,66 opposed-view QPI,67 and multimodal imaging.68 In this study, the application of SMIM is expanded to the field of DLHM-based QPI. Hence, LESSMIM implements a common-path off-axis interferometric configuration by assembling an illumination unit including a one-dimensional (1D) diffraction grating and by spatially multiplexing the sample plane. From a recorded off-axis hologram, LESSMIM achieves QPI by Fourier filtering-based reconstruction, aberration compensation, and numerical propagation. Section 2 describes the concept and layout of our approach. Section 3 presents the experimental validation of LESSMIM using technical test targets, microspheres, and living cells. Experimental validations with living cells comprise evaluations with adherent cells having different sizes as well as evaluations with cells in flow using a microfluidic system with hydrodynamic focusing. Finally, Sec. 4 presents the discussion and conclusions of the proposed technique. 2.LESSMIM Concept and Experimental SetupFigure 1 illustrates the optical concept of LESSMIM, consisting of an illumination unit and a digital recording sensor. Collimated coherent illumination is achieved by a fiber-coupled laser diode applying a collimating lens with the focal length . A sinusoidal diffraction grating diffracts the illumination wave into three fractions, which are focused by an additional lens with an image focal length to generate three spatially separated point sources in the focal plane. These replicas are laterally separated a distance where is the spatial frequency of the grating, defined as the inverse of the spatial period of the grating periodic structures, and represents the wavelength of the illuminating laser light.69 The three resulting point sources, which correspond to the three diffraction orders of the grating, are located at a distance from the sample plane. The sample plane is divided into three regions from which one is blocked [object (), reference (), and blocking ()], similar to previously reported SMIM implementations.60,63,65 The blocking region prevents spurious interferences, whereas the object and reference regions are areas with and without the sample for simultaneous object and reference wave transmission, respectively. The arrangement of these regions is shown in the upper panel of Fig. 1. The blocking region can be achieved in different ways: either a customized chamber with an opaque region is fabricated, a limiting aperture is placed at the plane where the point sources are generated to block one of the point sources, or a border of the opaque frame of the diffraction grating is used to block only a portion (one third) of the beam to produce the blocking effect. The most general use case to provide the blocking region is using an opaque border of the grating, but the choice of the different blocking options will depend on the experimental requirements of the specific setup. A digital sensor is positioned at a distance from the sample plane to record an off-axis digital hologram. The recorded hologram results from the coherent overlapping between the Fresnel diffraction pattern from the region (0th diffraction order) and the non-perturbed light from the sample free region ( order). Further details about the system alignment are provided in Sec. S1 of the Supplemental Material. Due to the divergence of the sample illumination, the recorded diffraction pattern of the object region is geometrically magnified with magnification according to the relation70The field of view (FOV) is determined by the size of the CMOS recording area and magnification as where is the number of pixels in each transversal direction and is the pixel pitch of the digital sensor.70 The lateral resolution is diffraction-limited and depends on the distance between the sample and sensor as well as on the sensor size as follows:70The experimental validation of the LESSMIM concept was performed by utilization of a single-mode fiber-coupled laser diode (Thorlabs LP515-SF3, output power 3 mW, central wavelength 515 nm) as the coherent illumination source. An achromatic collimating lens (Linos, AC focal length ) was used for collimation of the illuminating laser light, and a NA microscope lens (ZEISS LD Achroplan) was employed as the lens for beam focusing. Note that a specific microscope objective was used in the experimental validation of our concept, but more cost-effective optical lenses can be utilized. A Ronchi ruling (Edmund Optics, spatial frequency 120 line pairs/mm) served as a diffraction grating to generate the three-point sources. To generate the blocking region, we blocked one third of the beam with one opaque border of the Ronchi ruling frame. A monochrome CMOS sensor (TheImagingSource DMK23UP1300, , pixel size, image acquisition rate 95 fps) was employed for recording the generated digital off-axis holograms. Holograms were transferred to a computer via a USB 3.0 interface for numerical reconstruction and image processing downstream using MATLAB 2021b. Despite the rectangular shape of the digital sensor, a squared region of interest (ROI) of was defined to achieve an equal lateral resolution in the and directions, according to Eq. (4). The sample was positioned at a distance of from the point source and from the digital sensor. The entire setup had a length of 200 mm from the optical fiber tip to the digital sensor. According to Eq. (2), a magnification of was set, resulting in an FOV of , considering Eq. (3). Considering the above described optical and geometrical system parameters and Eq. (4), the theoretical spatial resolution is . 3.Experimental Validation3.1.Demonstration of the Operation Principle with a Resolution TargetIn the first step, the operation principle of LESSMIM was evaluated. For that, off-axis holograms from a resolution test target (positive 1951 USAF target, Thorlabs Inc., New Jersey, United States) were recorded. Figure 2 illustrates the subsequently performed numerical reconstruction process. Figure 2(a) shows a recorded off-axis Fresnel digital hologram with an included magnified inset depicting the generated parallel off-axis carrier fringe pattern. Figure 2(b) displays the corresponding well-separated site bands of the diffraction orders in the spatial frequency domain after a fast Fourier transformation. Fourier filtering was applied to one of the cross-correlation terms, as indicated with a dotted red circle in Fig. 2(b), to retrieve the complex object wave, as well as the corresponding amplitude [Fig. 2(c)] and phase [Fig. 2(d)] distributions of the diffracted light. The reconstructed phase image in Fig. 2(d) exhibits a comatic aberration. This aberration was generated by the propagation of the tilted reference wave across the focusing lens through a region outside the optical axis. To compensate for the comatic effect, an additional blank reference hologram of a clear region of the USAF test target without sample information was recorded. Alternatively, it is also possible to acquire a reference hologram without a sample in the optical path. The retrieved amplitude and phase distributions are included in Figs. 2(e) and 2(f). Subsequently, the retrieved complex waves with [Figs. 2(c) and 2(d)] and without [Figs. 2(e) and 2(f)] sample information, including amplitude and phase information, were subtracted by complex division of the object wave and the wave from the blank reference hologram. As evident in Figs. 2(g) and 2(h), the subtraction process efficiently removed aberrations, spurious reflections, and dust, resulting in a homogeneous image background. The further numerical propagation of the subtracted complex object wave to the image plane was performed utilizing the angular spectrum method71 yielding focused amplitude [Fig. 2(i)] and phase [Fig. 2(j)] images of the test chart structures. To compare LESSMIM with conventional DLHM, amplitude and phase images obtained by DLHM were recovered as follows: the diffraction grating was simply removed to record a conventional DLHM hologram without a separate reference wave. The reconstruction of the conventional hologram was performed by numerical propagation as described in Ref. 71, and a reference hologram without a sample was recorded and employed for achieving a homogeneous image background in the amplitude and phases images70 [Figs. 2(k) and 2(l)]. In both DLHM images [Figs. 2(k) and 2(l)], disturbances by twin-image presence are evident, whereas the images provided by LESSMIM [Figs. 2(i) and 2(j)] exhibit a considerably higher contrast. The quality improvement of the amplitude and phase images achieved by LESSMIM is also indicated by the enlarged color-coded areas shown in Fig. 2(m) [see also blue and yellow rectangular frames in Figs. 2(i)–2(l)], in which the smallest elements of the applied USAF resolution test target are resolved (element 6 - group 7, G7-E6, period ). These observations are also supported by the cross-section profiles through the amplitude images [Fig. 2(n)] along the blue and red lines included in Figs. 2(i) and 2(k). Due to the smallest available structures of the applied USAF test target, the confirmed spatial resolution is lower than the theoretical value calculated in Sec. 2. For a more precise verification of the maximum achievable spatial resolution, a calibrated high-resolution USAF target, including group 8, element 6, which corresponds to a period of , is required. 3.2.Temporal StabilityThe temporal stability of LESSMIM was assessed by measuring phase fluctuations over time. Therefore, a blank microscope slide was placed at the sample location, and 300 off-axis holograms were sequentially recorded over a period of 5 min at a hologram acquisition rate of 1 Hz. After numerical QPI image reconstruction, within an ROI of , the variation of the average phase of each frame with respect to the average phase of the initially acquired QPI image was determined. The plot of the temporal development is presented in Fig. 3(a). Figure 3(b) depicts the spatial distribution corresponding of the standard deviation (STD) that was calculated for each pixel of the entire stack of 300 QPI images. The corresponding histogram of the computed values is depicted in Fig. 3(c). The mean value indicates a high temporal phase stability. 3.3.Evaluation of QPI Accuracy Using MicrospheresThe performance of LESSMIM for QPI was validated experimentally by analyzing PMMA microspheres with a diameter of (PolyAn GmbH, lot number PT1140130FS) that were immersed in a mixture of glycerin and water (90%/10%). Figure 4(a) depicts a recorded digital off-axis hologram of . The enlarged area of the yellow-framed region visualizes the off-axis carrier fringe pattern. Following the recovery process described in Sec. 3.1, the numerically focused QPI image of the microsphere enclosed in the red-framed square of Fig. 4(a) is obtained [Fig. 4(b)]. Here, a blank reference hologram was achieved by imaging a region of the sample without microspheres. Considering the refractive indices of the microspheres (Ref. 72) and the immersion liquid (measured with an Abbe refractometer at ), the thickness distribution of the microsphere was computed from the background-corrected phase distribution of the QPI image in Fig. 4(b) and the RI difference between the microspheres and the surrounding glycerol-water mixture.73 A pseudo-three-dimensional (3D) representation of the microsphere thickness distribution is presented in Fig. 4(c). Figure 4(d) shows a thickness profile along the dotted blue line in Fig. 4(b). To obtain the maximum thickness of the microsphere, we evaluated 10 data points around the center of the microsphere from which the mean value as well as the standard deviation were calculated. The obtained value for the maximum thickness matches the microsphere diameter of provided by the manufacturer and validates LESSMIM for accurate QPI. 3.4.QPI of Living Adherently Grown Pancreatic Tumor CellsTo assess the capability of LESSMIM for QPI of biological samples, investigations on living adherent pancreatic tumor cells (PaTu 8988T) were performed.74,75 Subconfluently grown cells were observed in Dulbecco modified Eagle’s medium (DMEM) between a glass object carrier slide and a cover slip (thickness of ). A blank reference hologram was achieved by imaging a sample region without cells. Figure 5 presents experimental results from adherent cells. Rows include different adherent cells exhibiting different morphologies and thicknesses. The first column (a1 to a4) in Fig. 5 displays the recorded off-axis holograms. In the second column (b1 to b4) of Fig. 5, the corresponding numerically focused QPI images are shown. Similar to the analyzed microspheres in Sec. 3.3, the cell thickness was determined by considering an average cellular refractive index of 76 and a refractive index of of the culture medium (measured by an Abbe refractometer). Pseudo-3D visualizations of the resulting cell thickness distributions are plotted in the third column (c1 to c4) of Fig. 5. Finally, Figs. 5(d1)–5(d4) include thickness profiles along the dotted blue lines in Figs. 5(b1)–5(b4). Additional results from isolated PaTu 8988T single cells are shown in Fig. S1 in the Supplemental Material. The experimental results demonstrate that LESSMIM successfully provided QPI images of both adjacent and isolated living adherent cells having different morphologies and axial dimensions, even for the case of thin adherent cells (as shown in row 4 of Fig. 5). 3.5.Quantitative Phase Imaging of Cells in Flow Within a Microfluidic DeviceThe capability of LESSMIM for QPI of fast events and imaging flow cytometry (IFC) was evaluated by observation of living suspended PaTu 8988 T cells in a microfluidic chip within a rectangular cross-section (channel width of 1 mm and channel height of ) and hydrodynamic focusing capabilities as sketched in Fig. 6(a). The microfluidic device employed a syringe pump (Nemesys, CETONI GmbH, Korbußen, Germany) to direct the cells toward the microfluidic channel. The microfluidic channel was realized by standard soft lithography in polydimethylsiloxane (PDMS, Dow Corning, Midland, Michigan, United States), with a substrate that was 1 mm thick, and the PDMS was bonded on a glass coverslip (thickness of ) by an air-plasma activation as described in Refs. 77 and 78. To achieve lateral hydrodynamic focusing, the chip circuit was designed in co-flow architecture with an included inlet for splitting the sheath fluid into two separate fractions at the lateral channel borders and another inlet for the sample fluid in the center. The sheath fluid was introduced with two channels at an angle of 30 deg with respect to the channel for the sample fluid. The enlarged green-framed region in the right panel of Fig. 6(a) indicates the sample plane imaged by the LESSMIM setup and illustrates the need for hydrodynamic focusing to prevent the presence of cells within the reference area. For the experiments, Patu 8988 T cells were suspended in DMEM at concentrations of and observed with LESSMIM in a laminar flow at flow rates of and for the sheath fluid and the sample fluid, respectively. Off-axis holograms were recorded for 5 s at an acquisition rate of 40 fps and an exposure time of 2 ms. A blank reference hologram was recorded prior to the suspended cells passing through the microfluidic channel. The resulting holograms and QPI images are presented in Fig. 6 and Video 1. Figure 6(b) shows an exemplary off-axis hologram of a recorded image stack. The yellow arrow indicates the direction of the sample fluid stream. A representative-focused QPI image recovered from the hologram in Fig. 6(b) is depicted in Fig. 6(c). Figure 6(d) presents a pseudo-3D plot of the thickness distribution calculated from Fig. 6(c) by considering the same average RI value for PaTu 8988T cells as for the experiments in Sec. 3.4. Green outlines in Fig. 6(d) that were generated by the Otsu thresholding algorithm68 illustrate a reliable segmentation of cells in the QPI images and indicate the cellular boundaries. Figures 6(e) and 6(f) show images generated by maximum intensity projection (MIP) using Fiji,79 in which all cells that were detected in the recorded QPI image stack are visible. Figure 6(e) displays the combined image of the recovered focused QPI images, and Fig. 6(f) presents the corresponding image of the pseudo-3D thickness distributions with outlined cellular boundaries. To further evaluate the suitability of LESSMIM for IFC, biophysical features including the projected radius, integral refractive index, and cellular dry mass of the investigated cells in flow were determined from the recorded QPI image stacks. A total of 300 single cells (included in Video 1) were segmented and analyzed, whereas clustered cells in the respective images were discarded. Therefore, in the first step, segmentation was performed in each QPI image of a recorded stack, as illustrated in Fig. 6(c), to determine the projected area of every analyzed single cell. Subsequently, assuming a spherical shape, as typical for suspended PaTu 8988 T cells,75 the cell radius was calculated from the parameter as . Moreover, as described in Refs. 75 and 76, the cellular dry mass was calculated from the average phase value induced by the analyzed cell and the RI increment of the intracellular content, which was estimated to be for the investigated pancreatic tumor cell line.80 Finally, the integral RI of the cells was computed, where represents the mean cell thickness determined from QPI images of spherical cells as described in Refs. 75 and 76. Figure 7(a) shows the plot of the retrieved integral cellular RI versus the corresponding projected cell radius for the 300 analyzed cells, and Fig. 7(b) displays the relative frequency histogram of the corresponding dry mass DM values. The mean values , , and are in good agreement with experimental data from previous investigations on PaTu 8988T cells.76 4.Discussion and ConclusionsIn this study, we propose lensless spatially multiplexed interferometric microscopy (LESSMIM) as a single-shot DLHM technique to provide accurate QPI reconstruction and twin-image removal. LESSMIM is a simplified variant of the previously reported SMIM concept,60,63 in which imaging lenses are no longer required. LESSMIM comprises a common-path interferometric architecture that is based on a single diffraction grating to achieve digital off-axis holography. QPI of biomedical samples is achieved from single off-axis holograms using Fourier filtering and numerical propagation procedures. First, we characterized the technique concerning the lateral resolution (Fig. 2), temporal stability (Fig. 3), and QPI accuracy (Fig. 4) by utilizing a USAF resolution test target, a blank object carrier slide, and PMMA microspheres, respectively. Moreover, we demonstrated, for the example of pancreatic tumor cells, the capabilities of LESSMIM for QPI of living adherent cells (Fig. 5, Fig. S1 in the Supplemental Material) with different morphologies and thicknesses and for the retrieval of sets of biophysical parameters from fast-moving cellular specimens within a microfluidic channel with hydrodynamic focusing capabilities (Figs. 6 and 7). LESSMIM offers several advantages over other DHM techniques. It utilizes a common-path interferometric architecture that leads to higher temporal stability and lower demands on the coherence properties of the utilized light source than double-path schemes.64,81–83 Although in our study, the geometry and the quality of optics in the illumination unit were selected to achieve a flexible experimental arrangement, LESSMIM permits a simpler, more compact, and more cost-effective design than typical Mach-Zehnder interferometer-based DHM arrangements.8,14,15,84 In particular, when LESSMIM is compared with common-path DHM systems such as diffraction phase microscopy,82 LESSMIM avoids the use and precise alignment of spatial filters, but at the cost of requiring a blank reference region near the specimen. Moreover, due to the spherical divergent wavefront employed for sample illumination, it enables variable magnification by simply changing the axial position of the point sources while maintaining spatial resolution.70 This characteristic allows for flexibility in the FOV size, which can be extended up to the size of the digital sensor for a magnification equal to 1 [see Eq. (3)], as in wide-field on-chip microscopy.48,85 With respect to previously reported in-line DLHM approaches, LESSMIM overcomes the limitation of the twin image presence and enables an accurate reconstruction of QPI images. Moreover, in comparison with earlier reported off-axis DLHM concepts that are based on two-pinholes, Fresnel biprism, a pair of GRIN lenses, or a prism with two-volume hologram gratings, the diffraction grating-based off-axis principle of LESSMIM offers a simplified arrangement, alignment, and handling; improved light transmission efficiency; and increased cost effectiveness.56–59 In addition, LESSMIM provides similar or even higher spatial resolution than previously reported off-axis DLHM approaches56–59 and an FOV comparable to or slightly higher than that described in previous works.56,59 Regarding accuracy and temporal stability, only a few previously reported related approaches58,59 analyzed these features. In this study, we demonstrated that LESSMIM provides accurate QPI images and a temporal stability at an observation period of 5 min that is comparable to previously reported approaches.58,59 However, LESSMIM also has limitations. In LESSMIM, an object-free region near the sample is required, which limits the analysis of extended samples, as happens in lens-based SMIM systems.60,63 However, this issue can be addressed by customized micropatterned sample carriers.86 When LESSMIM is combined with a microfluidic system for IFC, this drawback can be overcome by either designing a microfluidic channel with a small width or, as in our study, employing microfluidic systems with hydrodynamic focusing. The spatially multiplexed approach also reduces the object region to one third of the illuminated FOV. However, in practice, this limitation is not significant as the illuminated sample region typically is larger than the recorded FOV. Another limitation of LESSMIM is the recording of out-of-focus holograms because it requires numerical propagation algorithms to achieve sharply focused QPI images, which increases the computational amounts and prevents correlative imaging with other modalities, such as fluorescence or bright field microscopy. Moreover, the system introduces coma aberration, which can be compensated for by either recording an additional reference hologram (as shown in Fig. 2), using various established state-of-the-art computational methods87,88 such as the utilization of Zernike polynomials,89 or more recent approaches such as principal component analysis90 or deep learning,91 etc.92,93 It is worth noting that this issue is not critical for the application of LESSMIM to IFC because a reference hologram can be recorded at the beginning of the experiment when no sample fluid is present inside the microfluidic channel. When compared with state-of-the-art DLHM systems, the LESSMIM setup presents relatively large axial dimensions (around 200 mm), but it can be further reduced by optimization of the axial distances (lenses with lower focal lengths and/or a smaller separation between lenses). In summary, LESSMIM has been demonstrated to be a compact and cost-effective method for accurate QPI that is also capable of imaging fast biomedical events. Future developments include the further miniaturization of the setup, investigations on optical components for further cost reduction, and methods for digital correction of phase aberrations. In particular, we will investigate changing the microscope objective, utilized in our study for illumination focusing, to a more cost-effective lens with a high numerical aperture for which additional aberrations can be assumed and that can be addressed numerically by adapted aberration correction algorithms. In addition, investigations to further reduce optical elements and space within the illumination unit will be performed to minimize the dimensions of the LESSMIM setup and to increase the cost effectiveness. LESSMIM will be useful for applications in various biomedical fields, particularly those for which analysis of fast-moving samples is required such as imaging flow cytometry94 or sperm assessment,25 as it is a DHM technique particularly valuable for point-of-care diagnosis and laboratories with limited budgets. DisclosuresThe authors declare that there are no conflicts of interest, financial or otherwise, related to this article. Code and Data AvailabilityData underlying the results presented in this article are available by a reasonable request to the corresponding authors. AcknowledgmentsThis work has been partially funded by MCIN/AEI/10.13039/501100011033 (Grant No. PID2020-120056GB-C21). J.A.P.B. is supported by the Spanish Grant “Margarita Salas” (Grant No. MS21-100) of the Ministry of Universities of the Government of Spain (Grant No. UP2021-044) funded by the European Union, NextGenerationEU. We further acknowledge support from the Open Access Publication Fund of the University of Muenster. Moreover, the authors would like to thank the Nonlinear Photonics Group from the Institute of Applied Physics at the University of Muenster for providing the microfluidics system with special thanks go to Dr. Riccardo Zamboni for his assistance and technical support with the microfluidic devices. ReferencesM. K. Kim, Digital holographic microscopy. Principles, techniques, and applications, Springer US(
(2011). Google Scholar
Y. K. Park, C. Depeursinge and G. Popescu,
“Quantitative phase imaging in biomedicine,”
Nat. Photonics, 12
(10), 578
–589 https://doi.org/10.1038/s41566-018-0253-x NPAHBY 1749-4885
(2018).
Google Scholar
B. Kemper et al.,
“Label-free quantitative in vitro live cell imaging with digital holographic microscopy,”
Bioanalytical Reviews, 2 Springer, Cham
(2019). Google Scholar
F. Zernike,
“Phase contrast, a new method for the microscopic observation of transparent objects,”
Physica, 9
(7), 686
–698 https://doi.org/10.1016/S0031-8914(42)80035-X
(1942).
Google Scholar
R. Allen, G. David and G. Nomarski,
“The Zeiss-Nomarski differential interference equipment for transmitted-light microscopy,”
Zeitschrift fur wissenschaftliche Mikroskopie, 69
(4), 193
–221
(1969).
Google Scholar
P. Marquet, C. Depeursinge and P. J. Magistretti,
“Review of quantitative phase-digital holographic microscopy: promising novel imaging technique to resolve neuronal network activity and identify cellular biomarkers of psychiatric disorders,”
Neurophotonics, 1
(2), 020901 https://doi.org/10.1117/1.NPh.1.2.020901
(2014).
Google Scholar
H. Majeed et al.,
“Quantitative phase imaging for medical diagnosis,”
J. Biophotonics, 10
(2), 177
–205 https://doi.org/10.1002/jbio.201600113
(2017).
Google Scholar
P. Marquet et al.,
“Digital holographic microscopy: a noninvasive contrast imaging technique allowing quantitative visualization of living cells with subwavelength axial accuracy,”
Opt. Lett., 30
(5), 468
–470 https://doi.org/10.1364/OL.30.000468 OPLEDP 0146-9592
(2005).
Google Scholar
P. Ferraro et al.,
“Extended focused image in microscopy by digital holography,”
Opt. Express, 13
(18), 6738
–6749 https://doi.org/10.1364/OPEX.13.006738 OPEXFF 1094-4087
(2005).
Google Scholar
B. Kemper and G. von Bally,
“Digital holographic microscopy for live cell applications and technical inspection,”
Appl. Opt., 47
(4), A52
–A61 https://doi.org/10.1364/AO.47.000A52 APOPAI 0003-6935
(2008).
Google Scholar
M. K. Kim,
“Principles and techniques of digital holographic microscopy,”
SPIE Rev., 1
(1), 018005 https://doi.org/10.1117/6.0000006
(2010).
Google Scholar
G. Popescu, Quantitative phase imaging of cells and tissues, McGraw-Hill(
(2011). Google Scholar
P. Picart, New techniques in digital holography, iSTE Press and John Wiley & Sons, London
(2015). Google Scholar
F. Dubois et al.,
“Digital holographic microscopy for the three-dimensional dynamic analysis of in vitro cancer cell migration,”
J. Biomed. Opt., 11
(5), 054032 https://doi.org/10.1117/1.2357174 JBOPFO 1083-3668
(2006).
Google Scholar
B. Kemper et al.,
“Investigation of living pancreas tumor cells by digital holographic microscopy,”
J. Biomed. Opt., 11
(3), 034005 https://doi.org/10.1117/1.2204609 JBOPFO 1083-3668
(2006).
Google Scholar
M. Ugele et al.,
“Label-free high-throughput leukemia detection by holographic microscopy,”
Adv. Sci., 5
(12), 1800761 https://doi.org/10.1002/advs.201800761
(2018).
Google Scholar
J. Kühn et al.,
“Label-free cytotoxicity screening assay by digital holographic microscopy,”
Assay Drug Dev. Technol., 11
(2), 101107 https://doi.org/10.1089/adt.2012.476
(2013).
Google Scholar
K. M. Eder et al.,
“Label-free digital holographic microscopy for in vitro cytotoxic effect quantification of organic nanoparticles,”
Cells, 11
(4), 644 https://doi.org/10.3390/cells11040644
(2022).
Google Scholar
A. Marzi et al.,
“Interlaboratory evaluation of a digital holographic microscopy–based assay for label-free in vitro cytotoxicity testing of polymeric nanocarriers,”
Drug Deliv. Transl. Res., 12
(9), 2207
–2224 https://doi.org/10.1007/s13346-022-01207-5
(2022).
Google Scholar
Á. Barroso et al.,
“Three-dimensional exploration and mechano-biophysical analysis of the inner structure of living cells,”
Small, 9
(6), 885
–893 https://doi.org/10.1002/smll.201201851 SMALBC 1613-6810
(2013).
Google Scholar
V. L. Calin et al.,
“Digital holographic microscopy evaluation of dynamic cell response to electroporation,”
Biomed. Opt. Express, 12
(4), 2519
–2530 https://doi.org/10.1364/BOE.421959 BOEICL 2156-7085
(2021).
Google Scholar
D. R. Steike et al.,
“Digital holographic microscopy for label-free detection of leukocyte alternations associated with perioperative inflammation after cardiac surgery,”
Cells, 11
(4), 755 https://doi.org/10.3390/cells11040755
(2022).
Google Scholar
K. L. vom Werth et al.,
“Application of digital holographic microscopy to analyze changes in t-cell morphology in response to bacterial challenge,”
Cells, 12
(5), 762 https://doi.org/10.3390/cells12050762
(2023).
Google Scholar
G. Di Caprio et al.,
“Holographic imaging of unlabelled sperm cells for semen analysis: a review,”
J. Biophotonics, 8
(10), 779
–789 https://doi.org/10.1002/jbio.201400093
(2015).
Google Scholar
C. Soler et al.,
“Effect of counting chamber depth on the accuracy of lensless microscopy for the assessment of boar sperm motility,”
Reprod. Fertil. Dev., 30
(6), 924
–934 https://doi.org/10.1071/RD17467 RFDEEH 1031-3613
(2018).
Google Scholar
A. Anand et al.,
“Automatic identification of malaria-infected RBC with digital holographic microscopy using correlation algorithms,”
IEEE Photonics J., 4
(5), 1456
–1464 https://doi.org/10.1109/JPHOT.2012.2210199
(2012).
Google Scholar
A. Doblas et al.,
“Diabetes screening by telecentric digital holographic microscopy,”
J. Microsc., 261
(3), 285
–290 https://doi.org/10.1111/jmi.12331 JMICAR 0022-2720
(2016).
Google Scholar
N. Goswami et al.,
“Label-free SARS-CoV-2 detection and classification using phase imaging with computational specificity,”
Light Sci. Appl., 10 176 https://doi.org/10.1038/s41377-021-00620-8
(2021).
Google Scholar
Y. Wu and A. Ozcan,
“Lensless digital holographic microscopy and its applications in biomedicine and environmental monitoring,”
Methods, 136 4
–16 https://doi.org/10.1016/j.ymeth.2017.08.013 MTHDE9 1046-2023
(2018).
Google Scholar
D. Gabor,
“A new microscopic principle,”
Nature, 161
(4098), 777
–778 https://doi.org/10.1038/161777a0
(1948).
Google Scholar
J. Garcia-sucerquia et al.,
“Digital in-line holographic microscopy,”
Appl. Opt., 45
(5), 836
–850 https://doi.org/10.1364/AO.45.000836 APOPAI 0003-6935
(2006).
Google Scholar
W. Xu et al.,
“Digital in-line holography for biological applications,”
Proc. Natl. Acad. Sci., 98
(20), 11301
–11305 https://doi.org/10.1073/pnas.191361398
(2001).
Google Scholar
V. Micó et al.,
“Phase-shifting Gabor holography,”
Opt. Lett., 34
(10), 1492
–1494 https://doi.org/10.1364/OL.34.001492 OPLEDP 0146-9592
(2009).
Google Scholar
V. Micó and J. García,
“Common-path phase-shifting lensless holographic microscopy,”
Opt. Lett., 35
(23), 3919
–3921 https://doi.org/10.1364/OL.35.003919 OPLEDP 0146-9592
(2010).
Google Scholar
Y. Rivenson et al.,
“Sparsity-based multi-height phase recovery in holographic microscopy,”
Sci. Rep., 6 37862 https://doi.org/10.1038/srep37862 SRCEC3 2045-2322
(2016).
Google Scholar
O. Mudanyali et al.,
“Compact, light-weight and cost-effective microscope based on lensless incoherent holography for telemedicine applications,”
Lab Chip, 10 1417
–1428 https://doi.org/10.1039/c000453g LCAHAM 1473-0197
(2010).
Google Scholar
G. Biener et al.,
“Combined reflection and transmission microscope for telemedicine applications in field settings,”
Lab Chip, 11
(16), 2738
–2743 https://doi.org/10.1039/c1lc20169g LCAHAM 1473-0197
(2011).
Google Scholar
D. W. E. Noom et al.,
“High-speed multi-wavelength Fresnel diffraction imaging,”
Opt. Express, 22
(25), 30504
–30511 https://doi.org/10.1364/OE.22.030504 OPEXFF 1094-4087
(2014).
Google Scholar
M. Sanz et al.,
“Improved quantitative phase imaging in lensless microscopy by single-shot multi-wavelength illumination using a fast convergence algorithm,”
Opt. Express, 23
(16), 21352 https://doi.org/10.1364/OE.23.021352 OPEXFF 1094-4087
(2015).
Google Scholar
M. Sanz et al.,
“Compact, cost-effective and field-portable microscope prototype based on MISHELF microscopy,”
Sci. Rep., 7
(1), 1
–12 SRCEC3 2045-2322
(2017).
Google Scholar
J. Á. Picazo-Bueno et al.,
“Multi-illumination single-holographic-exposure lensless Fresnel (MISHELF) microscopy: principles and biomedical applications,”
Sensors, 23
(3), 1472 https://doi.org/10.3390/s23031472 SNSRES 0746-9462
(2023).
Google Scholar
G. Pedrini et al.,
“Whole optical wave field reconstruction from double or multi in-line holograms by phase retrieval algorithm,”
Opt. Express, 11
(24), 3234
–3241 https://doi.org/10.1364/OE.11.003234 OPEXFF 1094-4087
(2003).
Google Scholar
G. Pedrini, W. Osten and Y. Zhang,
“Wave-front reconstruction from a sequence of interferograms recorded at different planes,”
Opt. Lett., 30
(8), 833
–835 https://doi.org/10.1364/OL.30.000833 OPLEDP 0146-9592
(2005).
Google Scholar
P. Bao et al.,
“Phase retrieval using multiple illumination wavelengths,”
Opt. Lett., 33
(4), 309
–311 https://doi.org/10.1364/OL.33.000309 OPLEDP 0146-9592
(2008).
Google Scholar
L. Camacho et al.,
“Quantitative phase microscopy using defocusing by means of a spatial light modulator,”
Opt. Express, 18
(7), 6755
–6766 https://doi.org/10.1364/OE.18.006755 OPEXFF 1094-4087
(2010).
Google Scholar
P. Bao et al.,
“Lensless phase microscopy using phase retrieval with multiple illumination wavelengths,”
Appl. Opt., 51
(22), 5486
–5494 https://doi.org/10.1364/AO.51.005486 APOPAI 0003-6935
(2012).
Google Scholar
A. Greenbaum and A. Ozcan,
“Maskless imaging of dense samples using pixel super-resolution based multi-height lensfree on-chip microscopy,”
Opt. Express, 20
(3), 3129 https://doi.org/10.1364/OE.20.003129 OPEXFF 1094-4087
(2012).
Google Scholar
A. Greenbaum et al.,
“Imaging without lenses: achievements and remaining challenges of wide-field on-chip microscopy,”
Nat. Methods, 9 889
–895 https://doi.org/10.1038/nmeth.2114 1548-7091
(2012).
Google Scholar
A. Greenbaum et al.,
“Wide-field computational imaging of pathology slides using lens-free on-chip microscopy,”
Sci. Transl. Med., 6
(267), 175 https://doi.org/10.1126/scitranslmed.3009850 STMCBQ 1946-6234
(2014).
Google Scholar
J. R. Fienup,
“Phase retrieval algorithms: a comparison,”
Appl. Opt., 21
(15), 2758
–2769 https://doi.org/10.1364/AO.21.002758 APOPAI 0003-6935
(1982).
Google Scholar
Y. Rivenson et al.,
“Phase recovery and holographic image reconstruction using deep learning in neural networks,”
Light Sci. Appl., 7
(2), 17141
–17141 https://doi.org/10.1038/lsa.2017.141
(2017).
Google Scholar
Y. C. Wu et al.,
“Air quality monitoring using mobile microscopy and machine learning,”
Light Sci. Appl., 6
(9), e17046 https://doi.org/10.1038/lsa.2017.46
(2017).
Google Scholar
Z. Göröcs et al.,
“A deep learning-enabled portable imaging flow cytometer for cost-effective, high-throughput, and label-free analysis of natural water samples,”
Light Sci. Appl., 7 66 https://doi.org/10.1038/s41377-018-0067-0
(2018).
Google Scholar
Y. Rivenson, Y. Wu and A. Ozcan,
“Deep learning in holography and coherent imaging,”
Light Sci. Appl., 8 85 https://doi.org/10.1038/s41377-019-0196-0
(2019).
Google Scholar
T. Liu et al.,
“Deep learning-based holographic polarization microscopy,”
ACS Photonics, 7
(11), 3023
–3034 https://doi.org/10.1021/acsphotonics.0c01051
(2020).
Google Scholar
Y. Lu, Y. Liu and T. K. Lau,
“Simple, portable, and low-cost microscope based on off-axis digital holography using two spherical waves,”
Opt. Lett., 39
(15), 4549
–4552 https://doi.org/10.1364/OL.39.004549 OPLEDP 0146-9592
(2014).
Google Scholar
E. Serabyn et al.,
“Compact, lensless digital holographic microscope for remote microbiology,”
Opt. Express, 24
(25), 28540
–28548 https://doi.org/10.1364/OE.24.028540 OPEXFF 1094-4087
(2016).
Google Scholar
M. Rostykus and C. Moser,
“Compact lensless off-axis transmission digital holographic microscope,”
Opt. Express, 25
(14), 16652
–16659 https://doi.org/10.1364/OE.25.016652 OPEXFF 1094-4087
(2017).
Google Scholar
S. Ebrahimi et al.,
“Common-path lensless digital holographic microscope employing a Fresnel biprism,”
Opt. Lasers Eng., 128 106014 https://doi.org/10.1016/j.optlaseng.2020.106014
(2020).
Google Scholar
V. Mico et al.,
“Spatially-multiplexed interferometric microscopy (SMIM): converting a standard microscope into a holographic one,”
Opt. Express, 22
(12), 14929 https://doi.org/10.1364/OE.22.014929 OPEXFF 1094-4087
(2014).
Google Scholar
J. Á. Picazo-Bueno et al.,
“Spatially multiplexed interferometric microscopy with partially coherent illumination,”
J. Biomed. Opt., 21
(10), 106007 https://doi.org/10.1117/1.JBO.21.10.106007 JBOPFO 1083-3668
(2016).
Google Scholar
M. Trusiak et al.,
“Single-shot two-frame π-shifted spatially multiplexed interference phase microscopy,”
J. Biomed. Opt., 24
(9), 096004 https://doi.org/10.1117/1.JBO.24.9.096004 JBOPFO 1083-3668
(2019).
Google Scholar
J. Á. Picazo-Bueno et al.,
“Spatially multiplexed interferometric microscopy: principles and applications to biomedical imaging,”
J. Phys. Photonics, 3
(3), 034005 https://doi.org/10.1088/2515-7647/abfc59
(2021).
Google Scholar
A. Anand, V. Chhaniwal and B. Javidi,
“Tutorial: common path self-referencing digital holographic microscopy,”
APL Photonics, 3
(7), 071101 https://doi.org/10.1063/1.5027081
(2018).
Google Scholar
J. Á. Picazo-Bueno et al.,
“Superresolved spatially multiplexed interferometric microscopy,”
Opt. Lett., 42
(5), 927 https://doi.org/10.1364/OL.42.000927 OPLEDP 0146-9592
(2017).
Google Scholar
J. Á. Picazo-Bueno et al.,
“Hilbert–Huang single-shot spatially multiplexed interferometric microscopy,”
Opt. Lett., 43
(5), 1007 https://doi.org/10.1364/OL.43.001007 OPLEDP 0146-9592
(2018).
Google Scholar
J. A. Picazo-Bueno and V. Micó,
“Opposed-view spatially multiplexed interferometric microscopy,”
J. Opt., 21
(3), 35701 https://doi.org/10.1088/2040-8986/ab000e
(2019).
Google Scholar
J. Á. Picazo-Bueno et al.,
“Single capture bright field and off-axis digital holographic microscopy,”
Opt. Lett., 48
(4), 876
–879 https://doi.org/10.1364/OL.478674 OPLEDP 0146-9592
(2023).
Google Scholar
J. W. Goodman, Introduction to Fourier Optics, Roberts(
(2005). Google Scholar
J. A. Picazo-Bueno et al.,
“Design, calibration, and application of a robust, cost-effective, and high-resolution lensless holographic microscope,”
Sensors, 22
(2), 553 https://doi.org/10.3390/s22020553 SNSRES 0746-9462
(2022).
Google Scholar
F. Shen and A. Wang,
“Fast-Fourier-transform based numerical integration method for the Rayleigh-Sommerfeld diffraction formula,”
Appl. Opt., 45
(6), 1102
–1110 https://doi.org/10.1364/AO.45.001102 APOPAI 0003-6935
(2006).
Google Scholar
M. N. Polyanskiy,
“Refractiveindex.info database of optical constants,”
Sci. Data, 11 94 https://doi.org/10.1038/s41597-023-02898-2
(2024).
Google Scholar
M. Born, E. Wolf,
“Principles of optics 7th edition,”
principles of optics electromagnetic theory of propagation interference and diffraction of light, Elsevier(
(1999). Google Scholar
H. P. Elsässer et al.,
“Establishment and characterisation of two cell lines with different grade of differentiation derived from one primary human pancreatic adenocarcinoma,”
Virchows Arch. B, 61
(1), 295
–306 https://doi.org/10.1007/BF02890431 VAAZA2 0340-6075
(1992).
Google Scholar
L. Kastl et al.,
“Quantitative phase imaging for cell culture quality control,”
Cytom. Part A, 91
(5), 470
–481 https://doi.org/10.1002/cyto.a.23082 1552-4922
(2017).
Google Scholar
J. Min et al.,
“Quantitative phase imaging of cells in a flow cytometry arrangement utilizing Michelson interferometer-based off-axis digital holographic microscopy,”
J. Biophotonics, 12
(9), e201900085 https://doi.org/10.1002/jbio.201900085
(2019).
Google Scholar
L. Zanini et al.,
“Opto-microfluidic integration of the Bradford protein assay in lithium niobate lab-on-a-chip,”
Sensors, 22
(3), 1144 https://doi.org/10.3390/s22031144 SNSRES 0746-9462
(2022).
Google Scholar
R. Zamboni et al.,
“Opto-microfluidic coupling between optical waveguides and tilted microchannels in lithium niobate,”
Opt. Express, 31
(17), 28423
–28436 https://doi.org/10.1364/OE.495406 OPEXFF 1094-4087
(2023).
Google Scholar
J. Schindelin et al.,
“Fiji: an open-source platform for biological-image analysis,”
Nat. Methods, 9
(7), 676
–682 https://doi.org/10.1038/nmeth.2019 1548-7091
(2012).
Google Scholar
R. Barer,
“Interference microscopy and mass determination,”
Nature, 169
(4296), 366
–367 https://doi.org/10.1038/169366b0
(1952).
Google Scholar
T. Kim et al.,
“White-light diffraction tomography of unlabelled live cells,”
Nat. Photonics, 8
(3), 256
–263 https://doi.org/10.1038/nphoton.2013.350 NPAHBY 1749-4885
(2014).
Google Scholar
B. Bhaduri et al.,
“Diffraction phase microscopy: principles and applications in materials and life sciences,”
Adv. Opt. Photonics, 6
(1), 57
–119 https://doi.org/10.1364/AOP.6.000057 AOPAC7 1943-8206
(2014).
Google Scholar
J. Zhang et al.,
“A review of common-path off-axis digital holography: towards high stable optical instrument manufacturing,”
Light Adv. Manuf., 2
(3), 333
–349 https://doi.org/10.37188/lam.2021.023
(2021).
Google Scholar
P. Ferraro et al.,
“Compensation of the inherent wave front curvature in digital holographic coherent microscopy for quantitative phase-contrast imaging,”
Appl. Opt., 42
(11), 1938 https://doi.org/10.1364/AO.42.001938 APOPAI 0003-6935
(2003).
Google Scholar
W. Bishara et al.,
“Lensfree on-chip microscopy over a wide field-of-view using pixel super-resolution,”
Opt. Express, 18
(11), 11181 https://doi.org/10.1364/OE.18.011181 OPEXFF 1094-4087
(2010).
Google Scholar
S. Mues et al.,
“Micro patterned surfaces: an effective tool for long term digital holographic microscopy cell imaging,”
Proc. SPIE, 10074 1007410 https://doi.org/10.1117/12.2253280 PSISDG 0277-786X
(2017).
Google Scholar
T. Colomb et al.,
“Total aberrations compensation in digital holographic microscopy with a reference conjugated hologram,”
Opt. Express, 14
(10), 4300 https://doi.org/10.1364/OE.14.004300 OPEXFF 1094-4087
(2006).
Google Scholar
T. Colomb et al.,
“Automatic procedure for aberration compensation in digital holographic microscopy and applications to specimen shape compensation,”
Appl. Opt., 45
(5), 851
–863 https://doi.org/10.1364/AO.45.000851 APOPAI 0003-6935
(2006).
Google Scholar
T. Colomb et al.,
“Numerical parametric lens for shifting, magnification, and complete aberration compensation in digital holographic microscopy,”
J. Opt. Soc. Am. A, 23
(12), 3177 https://doi.org/10.1364/JOSAA.23.003177 JOAOD6 0740-3232
(2006).
Google Scholar
C. Zuo et al.,
“Phase aberration compensation in digital holographic microscopy based on principal component analysis,”
Opt. Lett., 38
(10), 1724
–1726 https://doi.org/10.1364/OL.38.001724 OPLEDP 0146-9592
(2013).
Google Scholar
S. Ma et al.,
“Phase-aberration compensation via deep learning in digital holographic microscopy,”
Meas. Sci. Technol., 32
(10), 105203 https://doi.org/10.1088/1361-6501/ac0216 MSTCEP 0957-0233
(2021).
Google Scholar
J. Di et al.,
“Phase aberration compensation of digital holographic microscopy based on least squares surface fitting,”
Opt. Commun., 282
(19), 3873
–3877 https://doi.org/10.1016/j.optcom.2009.06.049 OPCOB8 0030-4018
(2009).
Google Scholar
S. Liu et al.,
“Automatic and robust phase aberration compensation for digital holographic microscopy based on minimizing total standard deviation,”
Opt. Lasers Eng., 134 106276 https://doi.org/10.1016/j.optlaseng.2020.106276
(2020).
Google Scholar
N. A. Turko and N. T. Shaked,
“Erythrocyte volumetric measurements in imaging flow cytometry using simultaneous three-wavelength digital holographic microscopy,”
Biomed. Opt. Express, 11
(11), 6649
–6658 https://doi.org/10.1364/BOE.404368 BOEICL 2156-7085
(2020).
Google Scholar
BiographyJosé Ángel Picazo-Bueno is a postdoctoral fellow at the University of Valencia, Spain, specializing in physics. He received his BS and MS degrees and his PhD in physics from the University of Valencia in 2013, 2014, and 2020, respectively. With over 25 published journal papers and contributions to over 20 international conferences, his research focuses on digital holographic microscopy, quantitative phase imaging, lensless holography, and super-resolution imaging. Currently, he is conducting research at the Biomedical Technology Center of the University of Münster in Münster, Germany. He is an active member of SPIE. |
Digital holography
Holograms
Microscopy
Holography
Holographic interferometry
3D image reconstruction
Microfluidics