Paper
26 September 2013 X-ray pencil beam characterization of silicon pore optics
G. Vacanti, M. Ackermann, M. Vervest, M. Collon, R. Günther, C. Kelly, E. Wille, L. Cibik, M. Krumrey, P. Müller
Author Affiliations +
Abstract

The characterization of large aperture (> 2 meters), long focal length (> 10 meters) X-ray mirrors for X-ray astronomy with synchrotron radiation poses signi cant problems related to the available space at synchrotron radiation facilities. Intrafocal pencil beam characterization of part of the optics is advantageous if its results can be shown to have predictive capabilities with respect to the full system.

In this paper we present the routine characterization of silicon pore optics at the X-ray Pencil Beam Facility of the Physikalisch-Technische Bundesanstalt, located at the synchrotron radiation facility BESSY II (Berlin, Germany). In particular we show how measurements taken in the standard beamline con guration (detector at ve meters from the optics) can e ectively be used to predict the optical performance of the optics at their design focal length by comparing data taken on 20-meter focal length Silicon Pore Optics unit in the 20-meter beamline con guration (available only for a few weeks every year) with extrapolated 5-meter measurements.

© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
G. Vacanti, M. Ackermann, M. Vervest, M. Collon, R. Günther, C. Kelly, E. Wille, L. Cibik, M. Krumrey, and P. Müller "X-ray pencil beam characterization of silicon pore optics", Proc. SPIE 8861, Optics for EUV, X-Ray, and Gamma-Ray Astronomy VI, 88611K (26 September 2013); https://doi.org/10.1117/12.2024837
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Mirrors

X-ray optics

Sensors

Silicon

X-ray characterization

Beam shaping

RELATED CONTENT

Design of novel x-ray optical system for rocket experiment
Proceedings of SPIE (September 27 2013)
X-ray testing of silicon pore optics
Proceedings of SPIE (September 09 2019)
Upgrade of the x ray parallel beam facility XPBF 2.0...
Proceedings of SPIE (December 15 2020)
New x ray parallel beam facility XPBF 2.0 for the...
Proceedings of SPIE (July 11 2016)
The XEUS x-ray telescope
Proceedings of SPIE (June 13 2006)
X-ray pencil beam facility for optics characterization
Proceedings of SPIE (July 29 2010)
Active x ray optics for Generation X the next...
Proceedings of SPIE (June 15 2006)

Back to Top