Paper
31 December 2008 Three dimensional profilometry measurement based on grating projected method
Yanjun Fu, Minggang Chai, Huirong Xiao, Wendong Zou
Author Affiliations +
Proceedings Volume 7130, Fourth International Symposium on Precision Mechanical Measurements; 713047 (2008) https://doi.org/10.1117/12.819711
Event: Fourth International Symposium on Precision Mechanical Measurements, 2008, Anhui, China
Abstract
In the industrial detection, the three dimensional of the products are needed measuring usually, so the products can be known eligible or not. The measurement is needed both the high precision and fast speed. In the article, the smooth part of the mouse is taken as the measure object. Grating projected method is used to reconstruct the three dimensional of it. In the experiment, the intersect principle of fourier transform profilometry is used. The electronical grating is projected on the mouse, the deformed grating is collected in the Charge Coupled Device (CCD). And the deformed grating without the mouse is also collected. The fourier transform is used to process the image. In the traditional fourier transform profilometry, the phase is worked out as follows: After fourier transform, the zero frequency spectra is shifted to the origin of frequency, then filter the needed signal. Then the needed signal is shifted to the center of frequency, and then the zero frequency is shifted to both sides. After inverse fourier transform, the imaginary part is getting, so the phase is getting. But it has a difficult in the traditional method, because of three times frequency shift, and the center frequency is difficult to confirm, the frequency shift can't be correct and the filter can't be designed correctly. The error can be transferred, so the result of filter is not well, it has bad effect to the later measurement. The result of measurement is not well certainly. In order to conquer the difficult, after the fourier transform, filtering the needed signal without frequency shifting, then inverse fourier transform. So the phase of mouse relational with the frequency and coordinate is getting. The phase of the reference surface is getting by the same method. Then the difference phase is getting. At last, according to the relation of difference phase and the height in the grating projected method, the three dimensional profilometry of the mouse is reconstructed. The method is more simply and higher precision without three times frequency shift. The three dimensional profilometry reconstruct is realized by two images. It takes 0.3 second to reconstruct the three dimensional profilometry. The precision is 0.5mm. The result indicates that the method suits the smooth object with fast speed and high precision. It is fit for the needed in the practical measurement.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yanjun Fu, Minggang Chai, Huirong Xiao, and Wendong Zou "Three dimensional profilometry measurement based on grating projected method", Proc. SPIE 7130, Fourth International Symposium on Precision Mechanical Measurements, 713047 (31 December 2008); https://doi.org/10.1117/12.819711
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Fourier transforms

3D metrology

Image processing

3D image processing

Electronic filtering

Cameras

Optical filters

Back to Top