SCExAO at the Subaru telescope is a visible and near-infrared high-contrast imaging instrument employing extreme adaptive optics and coronagraphy. The instrument feeds the near-infrared light (JHK) to the integralfield spectrograph CHARIS. The spectropolarimetric capability of CHARIS is enabled by a Wollaston prism and is unique among high-contrast imagers. We present a detailed Mueller matrix model describing the instrumental polarization effects of the complete optical path, thus the telescope and instrument. From measurements with the internal light source, we find that the image derotator (K-mirror) produces strongly wavelength-dependent crosstalk, in the worst case converting ∼95% of the incident linear polarization to circularly polarized light that cannot be measured. Observations of an unpolarized star show that the magnitude of the instrumental polarization of the telescope varies with wavelength between 0.5% and 1%, and that its angle is exactly equal to the altitude angle of the telescope. Using physical models of the fold mirror of the telescope, the half-wave plate, and the derotator, we simultaneously fit the instrumental polarization effects in the 22 wavelength bins. Over the full wavelength range, our model currently reaches a total polarimetric accuracy between 0.08% and 0.24% in the degree of linear polarization. We propose additional calibration measurements to improve the polarimetric accuracy to <0.1% and plan to integrate the complete Mueller matrix model into the existing CHARIS post-processing pipeline. Our calibrations of CHARIS’ spectropolarimetric mode will enable unique quantitative polarimetric studies of circumstellar disks and planetary and brown dwarf companions.
SCExAO at the Subaru telescope is a visible and near-infrared high-contrast imaging instrument employing extreme adaptive optics and coronagraphy. The instrument feeds the near-infrared light (JHK) to the integral field spectrograph CHARIS. Recently, a Wollaston prism was added to CHARIS’ optical path, giving CHARIS a spectropolarimetric capability that is unique among high-contrast imaging instruments. We present a comprehensive and detailed Mueller matrix model describing the instrumental polarization effects of the complete optical path, thus the telescope and instrument, using measurements with the internal source and observations of standard stars. The 22 wavelength bins of CHARIS provide a unique opportunity to investigate in detail the wavelength dependence of the instrumental polarization effects. We find that the image derotator (K-mirror) produces strongly wavelength-dependent crosstalk, in the worst case converting ~95% of the incident linear polarization to circularly polarized light that cannot be measured. We fit the crosstalk of the half-wave plate (HWP) for all wavelengths with a simple two-parameter model of an achromatic HWP consisting of a layer of quartz and a layer of MgF2. While the magnitude of the telescope-induced polarization varies with wavelength, its angle varies solely with the altitude angle of the telescope. We show initial steps toward correcting on-sky data for the instrumental polarization effects, with which we aim to achieve a polarimetric accuracy <0.1% in the degree of linear polarization. Our calibrations of CHARIS’ spectropolarimetric mode enable unique quantitative polarimetric studies of circumstellar disks and planetary and brown dwarf companions.
Polarization Differential Imaging (PDI) is one of the most productive modes of current high-contrast imagers. Dozens of new protoplanetary, transition and debris disks were imaged recently for the first time, helping us understand the processes of planet formation, and giving clues on the mass of potential planets inside these disks, even if they cannot be imaged directly. The Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument is equipped with a fast visible dual-camera polarimetric module, VAMPIRES, already producing valuable scientific observations of protoplanetary disks and dust shells. In addition, we recently commissioned two new polarimetric modules in the infrared. The first one is a spectro-polarimetric mode using the CHARIS Integral Field Spectrograph (IFS). A Wollaston prism was added in front of the IFS, reducing the field-of-view to 2x1 arcsec to accommodate for the imaging of both polarizations on the same detector without sacrificing the spectral resolution of the instrument, in any of its spectral modes. The second module, similar to VAMPIRES, uses a low-noise high frame rate C-RED ONE camera combined with a Ferroelectric Liquid Crystal (FLC) device to modulate and record the polarization at high-speed, freezing effectively the atmospheric speckles for higher precision. We present on-sky results of the new polarimetric capabilities taken during the commissioning phase. In addition, we show future capabilities that are already scheduled to increase the performance of these modules, especially the addition of non-redundant masks, as well as a polarimetric vector Apodizing Phase Plate (vAPP) coronagraph.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.