19 September 2016 Performance of a Mach-Zehnder based analogue data recording system for use with the Gas Cherenkov Detector on the NIF
A. C. Carpenter, H. W. Herrmann, B. V. Beeman, F. E Lopez, J. E. Hernandez
Author Affiliations +
Abstract
This paper covers the performance of a high speed analogue data transmission system. This system uses multiple Mach- Zehnder optical modulators to transmit and record fusion burn history data for the Gas Cherenkov Detector (GCD) on the National Ignition Facility. The GCD is designed to measure the burn duration of high energy gamma rays generated by Deuterium-Tritium (DT) interactions in the NIF. The burn duration of DT fusion can be as short as 10ps and the optical photons generated in the gas Cherenkov cell are measured using a vacuum photodiode with a FWHM of ~55ps. A recording system with a 3dB bandwidth of ≥10GHz and a signal to noise ratio of ≥5 for photodiode output voltage of 50mV is presented. The data transmission system uses two or three Mach-Zehnder modulators and an RF amplifier to transmit data optically. This signal is received and recorded by optical to electrical converts and a high speed digital oscilloscope placed outside of the NIF Target Bay. Electrical performance metrics covered include signal to noise ratio (SNR), signal to peak to peak noise ratio, single shot dynamic range, shot to shot dynamic range, system bandwidth, scattering parameters, are shown. Design considerations such as self-test capabilities, the NIF radiation environment, upgrade compatibility, Mach-Zehnder (MZ) biasing, maintainability, and operating considerations for the use of MZs are covered. This data recording system will be used for the future upgrade of the GCD to be used with a Pulse Dilation PMT, currently under development.
Conference Presentation
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
A. C. Carpenter, H. W. Herrmann, B. V. Beeman, F. E Lopez, and J. E. Hernandez "Performance of a Mach-Zehnder based analogue data recording system for use with the Gas Cherenkov Detector on the NIF", Proc. SPIE 9966, Target Diagnostics Physics and Engineering for Inertial Confinement Fusion V, 996609 (19 September 2016); https://doi.org/10.1117/12.2237853
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Signal to noise ratio

National Ignition Facility

Photodiodes

Diagnostics

Amplifiers

Digital recording

Oscilloscopes

RELATED CONTENT

On the potential to enhance the spatial resolution of the...
Proceedings of SPIE (September 23 2013)
RIN measurements of the 850nm VCSELs
Proceedings of SPIE (September 28 2016)
Featuring in CCD imagers
Proceedings of SPIE (April 21 2006)
PV-MCT working standard radiometer
Proceedings of SPIE (May 18 2012)

Back to Top