Paper
20 August 2004 Investigation of subpellicle defect formation at KrF lithography
Author Affiliations +
Abstract
In this study we investigated the defect due to pellicle frame materials for repeating exposure in months. Defects were found in the sub-pellicle and the defect density was high in the 4 corners compared to the center of the mask. The defects grew on MoSiON or the interface Quartz and MoSiON film, and the defect size was below 0.5 um. By analyzing with Raman Spectroscopy, defects consist of Ammonium Sulfates, Melamine Formaldade Resin and KClO3. The evaluation method for cleaning process and pellicles was Ion Chromatography. According to Ion Chromatography analysis, the main composition of defect was substances of pellicle frame materials. Also we confirmed the pellicle frame effect with the exposure test.
© (2004) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Junsik Lee, Dong Wook Lee, Mun-Sik Kim, Ho-Yong Jung, and Oscar Han "Investigation of subpellicle defect formation at KrF lithography", Proc. SPIE 5446, Photomask and Next-Generation Lithography Mask Technology XI, (20 August 2004); https://doi.org/10.1117/12.557703
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Pellicles

Ions

Photomasks

Reticles

Adhesives

Inspection

Chemical analysis

Back to Top