Due to the ocular hemodynamics in the elastic eyeball, particularly the vascular volume changes of the choroid, several ocular elements experience a pulsatile movement, i.e., ocular pulse (OP).1,2 OP is highly correlated with the biomechanical properties of the eye and may also act as a surrogate for changes in choroidal blood flow. The ability to noninvasively monitor the OP in vivo may play an important role in a number of ocular diseases such as glaucoma, age-related macular degeneration, and diabetic retinopathy. Fourier-domain optical coherence tomography (FDOCT) is a promising noninvasive method for high-resolution and dynamic eye imaging. Making use of the high-axial resolution of the FDOCT, the axial displacements of cornea and retina and the fundus pulse were measured by tracking the tissue position in sequential structural images.3–5 Generally, the precision of the intensity-based measurement is limited and is highly dependent on the accuracy of image segmentation. In order to suppress the segment-error-induced noise, the movement was processed using a bandpass filter at cardiac frequency.4,5 However, such a bandpass filter at certain frequencies is not desirable for the measurement of the minute OP in the anterior chamber (termed as aOP and defined as the relative motion between cornea and crystalline lens). As we know, the anterior chamber is filled with aqueous humor, and the aOP would be closely correlated to the intraocular pressure (IOP). Accordingly, similar to the IOP, the aOP may also be affected by several factors of different frequencies such as heartbeat and respiration.6 Therefore, it would be particularly attractive to capture the aOP at a high sensitivity and a wide frequency-band to retain the valuable information which would otherwise be lost. In contrast, the phase shift during a time interval is inherently sensitive to the subwavelength displacement of scattering particles in the phase-sensitive OCT (PhS-OCT),7,8, according to the relation expressed by , where is the refractive index of the ocular tissue which is typically 1.36, and is the center wavelength used in OCT. The detectable displacement range of this phase-based method is bounded by the system signal-to-noise ratio (SNR) (lower limit, ) and the ambiguity (upper limit, ).8 Depending on the choice of the time interval , different velocity ranges can be achieved. However, there are several factors that make it challenging to visualize and quantify the dynamic aOP by the phase-based method. First, due to involuntary head movements and microsaccades, the small relative cornea-lens motion is accompanied with a large and time-variant bulk motion. Accordingly, the time interval (determined by the B-frame rate in PhS-OCT) should be carefully selected to make the velocity range cover both the slow relative motion and the fast bulk motion. Second, since the phase shift is calculated between successive B-frames in PhS-OCT, the accumulated phase drift caused by the random environmental vibrations is no longer negligible during such a long-time interval and requires reliable compensation. Here, we report for the first time the application of PhS-OCT to visualize the dynamic aOP in the rodent eye in vivo, along with optimized scanning protocols and equations for compensating bulk motion and random vibrations. Mice (strain C57BL/6) of 10 to 12 weeks of age were used in this experiment. All mice were raised and treated in compliance with the Association for Research in Vision and Ophthalmology statement. Mice were anesthetized by intraperitoneal injection. A total of six eyes were scanned by PhS-OCT. The PhS-OCT system is based on a spectral-domain configuration, similar to the system in Ref. 7. A broadband superluminescent light source with a central wavelength of 850 nm and a spectral bandwidth of 100 nm was used to achieve an axial resolution of in air. A high-speed spectrometer is used to record the OCT spectrum, providing a 70-kHz line scan rate and a measured imaging range of in air at half Fourier space. Based on the structural image, the cornea and lens components are generally above the noise floor [refer to Fig. 2(a)], i.e., the system phase noise can be considered as 0.03 rad. By tracking the cornea/lens position in the M-mode structural image [refer to Fig. 2(a)], the maximal velocity of the bulk motion can reach , whereas the velocity of the relative motion is in the range of several micrometers per second [refer to Fig. 2(c)]. To capture both the bulk and the relative motions, a B-frame rate of 780 fps was used to provide a theoretical detectable velocity range of 1.2 to at a wide detection band of 0 to 390 Hz (Nyquist theorem). Moreover, the slow scanning was stopped for repeated B-scanning in the horizontal meridians. In total, 3000 frames were collected covering a dynamic optical interval of . Figure 1(a) shows a wide-field OCT image of the full mouse eye using a full-range complex method, which has been detailed in Ref. 9 and is not elaborated here. In this study, the field of view is focused on the central part of anterior chamber [as marked by the rectangle in Fig. 1(a)] for dynamic imaging. As shown in Fig. 1(b), the raw phase cross-section can be generated based on the equation where is the complex OCT cross-sectional signal at the ’th acquisition of successive frames. The acquisition number can be related to the time by , and is the time interval between successive frames. denotes the complex conjugation of a complex signal. arg represents the operation of phase extraction. According to the depth information in the phase images , the raw cornea phase and the raw lens phase can be separated and, respectively, expressed as where is the phase difference corresponding to the relative motion between the cornea and the lens. and are the phase changes as a result of the bulk motion and the random vibrations, respectively. Therefore, as shown in Fig. 1(c), the relative phase difference can be extracted based on the following equation: where the raw cornea phase is reliably determined by a histogram-based phase selecting process.7,10In order to visualize the time-variant aOP, M-mode structural and phase images are generated along the center A-line of the B-frame (denoted as ) as shown in Figs. 2(a) and 2(b). The anterior and posterior corneal boundaries as well as the anterior lens boundary are segmented based on the derivative of the intensity signal in the -direction. As indicated in Fig. 2(b), the residual phase of the cornea component is around zero (green color), and the lens component presents a periodical variation versus time after compensation. Therefore, the compensated lens motion can be regarded as the relative cornea-lens motion, i.e., the aOP. To further quantify the aOP, the relative cornea-lens velocity () is plotted versus time along the depth [around the center part of the anterior lens, marked by the red bold arrows in Fig. 2(b)], based on the following equation: as reported by the red curve in Fig. 2(c). The residual cornea velocity is also plotted with a root-mean-square level of (i.e., minimal detectable velocity), as shown by the blue dashed line in Fig. 2(c). According to the power spectrum analysis, the relative velocity is mainly composed of two frequency components at 1.6 and 6.6 Hz, respectively. The low-frequency component 1.6 Hz is most likely due to the mouse respiration, whereas the 6.6-Hz frequency component is induced by the heartbeat. The relative displacement () pulse is readily obtained by integrating the velocity versus the time , as shown in Fig. 3(a). The waveform of the pulsatile is quite similar to the IOP variations due to the heartbeat and respiration, as reported in Ref. 6. According to the frequency analysis, the relative displacement is further decomposed into two components: the heartbeat-induced and the respiration-induced, as respectively shown in Figs. 3(b) and 3(c). According to the statistics generated from a total of six mouse eyes, the velocity amplitude is . The displacement amplitudes at the respiratory and cardiac frequencies are, respectively, and .This preliminary study demonstrates the feasibility of using a phase-based method for aOP imaging/measurement in vivo. The method provides a high sensitivity of minimal velocity at a wide detection band of 0 to 380 Hz. Further research could be performed to correlate the aOP to the fundus pulse, the choroidal blood flow, the IOP, and the biomechanical properties of the ocular tissue. AcknowledgementsWe acknowledge financial supports from the Chinese Natural Science Foundation (61335003, 61275196, and 61327007), Zhejiang Province Science and Technology Grant (2012C33031), Zhejiang Provincial Natural Science Foundation of China (LY14F050007), and the Fundamental Research Funds for the Central Universities (2014QNA5017). ReferencesD. M. SilverR. A. Farrell,
“Validity of pulsatile ocular blood flow measurements,”
Surv. Ophthalmol., 38
(Suppl), S72
–S80
(1994). http://dx.doi.org/10.1016/0039-6257(94)90049-3 SUOPAD 0039-6257 Google Scholar
J. C. Liet al.,
“The dynamic response of intraocular pressure and ocular pulse amplitude to acute hemodynamic changes in normal and glaucomatous eyes,”
Invest. Ophthalmol. Visual Sci., 54
(10), 6960
–6967
(2013). http://dx.doi.org/10.1167/iovs.13-12405 IOVSDA 0146-0404 Google Scholar
R. de Kinkelderet al.,
“Heartbeat-induced axial motion artifacts in optical coherence tomography measurements of the retina,”
Invest. Ophthalmol. Visual Sci., 52
(6), 3908
–3913
(2011). http://dx.doi.org/10.1167/iovs.10-6738 IOVSDA 0146-0404 Google Scholar
K. Singhet al.,
“Development of a novel instrument to measure the pulsatile movement of ocular tissues,”
Exp. Eye Res., 91
(1), 63
–68
(2010). http://dx.doi.org/10.1016/j.exer.2010.03.022 EXERA6 0014-4835 Google Scholar
K. Singhet al.,
“Measurement of ocular fundus pulsation in healthy subjects using a novel Fourier-domain optical coherence tomography,”
Invest. Ophthalmol. Visual Sci., 52
(12), 8927
–8932
(2011). http://dx.doi.org/10.1167/iovs.11-7854 IOVSDA 0146-0404 Google Scholar
R. L. Cooperet al.,
“Continual monitoring of intraocular pressure: effect of central venous pressure, respiration, and eye movements on continual recordings of intraocular pressure in the rabbit, dog, and man,”
Br. J. Ophthalmol., 63
(12), 799
–804
(1979). http://dx.doi.org/10.1136/bjo.63.12.799 BJOPAL 0007-1161 Google Scholar
P. Liet al.,
“Pulsatile motion of the trabecular meshwork in healthy human subjects quantified by phase-sensitive optical coherence tomography,”
Biomed. Opt. Express, 4
(10), 2051
–2065
(2013). http://dx.doi.org/10.1364/BOE.4.002051 BOEICL 2156-7085 Google Scholar
K. E. O’Haraet al.,
“Measuring pulse-induced natural relative motions within human ocular tissue in vivo using phase-sensitive optical coherence tomography,”
J. Biomed. Opt., 18
(12), 121506
(2013). http://dx.doi.org/10.1117/1.JBO.18.12.121506 JBOPFO 1083-3668 Google Scholar
P. Liet al.,
“Extended imaging depth to 12 mm for 1050-nm spectral domain optical coherence tomography for imaging the whole anterior segment of the human eye at 120-kHz A-scan rate,”
J. Biomed. Opt., 18
(1), 016012
(2013). http://dx.doi.org/10.1117/1.JBO.18.1.016012 JBOPFO 1083-3668 Google Scholar
V. X. D. Yanget al.,
“Improved phase-resolved optical Doppler tomography using the Kasai velocity estimator and histogram segmentation,”
Opt. Commun., 208
(4–6), 209
–214
(2002). http://dx.doi.org/10.1016/S0030-4018(02)01501-8 OPCOB8 0030-4018 Google Scholar
|